5915-01-033-5351 FILTER,BAND PASS Index 5915-01-033-5354 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-033-5352

Federal Supply Class:
5915

National Item Identification Number:
010335352

Description:
FILTER,LOW PASS

Detail:
An item designed to pass all frequencies below a specified frequency. Excludes a single inductance, a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
6091473-103640LOCKHEED MARTIN CORPORATION
LM360056216TELEDYNE WIRELESS, LLC


Techincal Specification:
AVERAGE POWER RATING PER FUNCTION2.0 WATTS BLANK LOCATION NOT OTHERWISE SPECIFIED
BODY OUTSIDE DIAMETER0.250 INCHES NOMINAL0.250 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS1.0 MAXIMUM BLANK AND 50.0 MINIMUM BLANK AND 75.0 MINIMUM BLANK FIRST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION2.00 GIGAHERTZ BLANK AND 3.60 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS0.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH2.125 INCHES NOMINAL2.125 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY2 CONNECTOR LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-54.0 TO 125.0 CELSIUS-54.0 TO 125.0 CELSIUS
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION2.8 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION2.00 GIGAHERTZ BLANK AND 3.60 GIGAHERTZ BLANK AND 5.40 GIGAHERTZ BLANK AND 7.20 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION2.0 GIGAHERTZ BLANK AND 3.6 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED