4810-01-033-5349 VALVE,SOLENOID Index 5915-01-033-5352 FILTER,LOW PASS

National Stock Number:
5915-01-033-5351

Federal Supply Class:
5915

National Item Identification Number:
010335351

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
299522810001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
90FP119901456MICROWAVE DEVELOPMENT LABORATORIES, INC.


Techincal Specification:
BODY HEIGHT2.000 INCHES NOMINAL
BODY MATERIALMETAL
BODY LENGTH5.015 INCHES NOMINAL
BODY WIDTH2.000 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM BLANK AND 60.0 MAXIMUM BLANK LOCATION NOT OTHERWISE SPECIFIED
FREQUENCY BAND WIDTH PER FUNCTION12.50 GIGAHERTZ BLANK AND 20.00 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 RECTANGULAR FLANGE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 RECTANGULAR FLANGE OUTPUT SECOND FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS2.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH7.500 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY2 FLANGE LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE+0.0 TO 70.0 CELSIUS
OVERALL HEIGHT3.577 INCHES NOMINAL
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONWAVEGUIDE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION16.0 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION9.00 GIGAHERTZ BLANK AND 12.50 GIGAHERTZ BLANK AND 20.00 GIGAHERTZ BLANK AND 23.00 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON TWO SURFACES
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED


Click here to Register for Free 30-day Trial