| END CONNECTION DESIGN | ELBOW FIRST END |
| END CONNECTION DESIGN | ELBOW SECOND END |
| END FLANGE CONSTRUCTION | SOLID FIRST END |
| END FLANGE CONSTRUCTION | SOLID SECOND END |
| BURST TEST PRESSURE | 2500.0 POUNDS PER SQUARE INCH |
| CONNECTION STYLE | PLAIN W/ GASKET GROOVE (SAE FLANGED HEAD) FIRST END |
| CONNECTION STYLE | PLAIN W/ GASKET GROOVE (SAE FLANGED HEAD) SECOND END |
| CONNECTION TYPE | PLAIN FACE FLANGE FIRST END |
| CONNECTION TYPE | PLAIN FACE FLANGE SECOND END |
| CROSS-SECTIONAL SHAPE STYLE | ROUND |
| FLANGE OUTSIDE DIAMETER | 1.990 INCHES MINIMUM AND 2.010 INCHES MAXIMUM FIRST END |
| FLANGE OUTSIDE DIAMETER | 1.990 INCHES MINIMUM AND 2.010 INCHES MAXIMUM SECOND END |
| FLANGE THICKNESS | 0.310 INCHES MINIMUM AND 0.320 INCHES MAXIMUM FIRST END |
| FLANGE THICKNESS | 0.310 INCHES MINIMUM AND 0.320 INCHES MAXIMUM SECOND END |
| FLANGE STYLE | ROUND W/ OUT BOLT HOLES FIRST END |
| FLANGE STYLE | ROUND W/ OUT BOLT HOLES SECOND END |
| FLOW ANGLE | 30.0 DEGREES FIRST END |
| FLOW ANGLE | 90.0 DEGREES SECOND END |
| INSIDE DIAMETER | 1.250 INCHES NOMINAL |
| INSIDE SURFACE CONDITION | SMOOTH |
| LAYER COMPOSITION AND LOCATION | 1ST LAYER BRAIDED CORROSION RESISTANT STEEL WIRE AND OUTER LAYER MOLDED RUBBER, CHLOROPRENE |
| OUTSIDE DIAMETER | 1.812 INCHES NOMINAL |
| MEASURING METHOD AND LENGTH | 166.000 INCHES NOMINAL OVERALL |
| MEDIA FOR WHICH DESIGNED | FUEL/OIL, HYDROCARBON SINGLE RESPONSE |
| MINIMUM INSIDE BENDING RADIUS | 16.000 INCHES |
| OPERATING PRESSURE | 625.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM LOCATION NOT OTHERWISE SPECIFIED |