SPECIFICATION/STANDARD DATA | 17B2N4009 MANUFACTURERS SPECIFICATION CONTROL |
USAGE DESIGN | PRECOOLER DIFFERENTIAL PRESSURE TRANSMITTER; TRANSMITTER SHALL SUPPLY A DIFFERENTIAL PRESSURE SIGNAL TO THE ENVIROMENTAL CONTROL SYSTEM CONTROLLER. THE TRANSMITTER MEASURES THE PRESSURE DIFFERENTIAL ACCROSS THE OVER PRESSURE SHUT OFF VALVE AND PRECOLLER |
VOLTAGE RATING | 0.5 POUNDS PER HOUR DRY OUTPUT AND 5.0 POUNDS PER HOUR WITH RETAINING CHAIN OUTPUT |
VOLTAGE RATING | 24.0 POUNDS PER HOUR DRY INPUT AND 34.0 POUNDS PER HOUR WITH RETAINING CHAIN INPUT |
ELECTRICAL CONNECTION CONTROLLING AGENCY | MILITARY SPEC |
ELECTRICAL CONNECTION IDENTIFYING NUMBER | M83723/90Y10066 |
ELECTRICAL CONNECTION QUANTITY | 1 |
ACTUATION METHOD | DIAPHRAGM |
CONTACT QUANTITY | 6 |
III CURRENT TYPE | DC |
PROPRIETARY CHARACTERISTICS | PACS |
MEASUREMENT RANGE | +0.0/+3.1 POUNDS PRESSURE PER SQUARE INCH |
MECHANICAL CONNECTION QUANTITY | 2 |
MECHANICAL CONNECTION SIZE | 0.437-20UNJF-3A |
MECHANICAL CONNECTION TYPE | FITTING END |
MOUNTING DEVICE QUANTITY | 1 |
MOUNTING METHOD | CLAMP |
NONDEFINITIVE SPEC/STD DATA | 1 NUMBER |
OVERALL DIAMETER | 1.470 INCHES MINIMUM AND 1.540 INCHES MAXIMUM |
OVERALL LENGTH | 5.840 INCHES NOMINAL |
REFERENCE DATA AND LITERATURE | DRAWING 17B2N4009 |
RELATIONSHIP TO SIMILAR EQUIPMENT | NOT INTERCHANGEABLE WITH 6685-01-370-2610 & 6685-01-387-5489 |
SPECIAL FEATURES | MEASUREMENT RANGE 0 TO 3.1PSID (DIFFERENTIAL PRESSURE), 0PSID = 0.5VDC, 3.1PSID = 3.6VDC |