| ELECTRICAL CONNECTION IDENTIFYING NUMBER | M83723/90Y1006N |
| ELECTRICAL CONNECTION QUANTITY | 1 |
| CONNECTOR CONTROLLING AGENCY | MILITARY SPEC |
| CONTACT QUANTITY | 6 |
| CURRENT TYPE | DC |
| OVERALL DIAMETER | 1.100 INCHES MINIMUM AND 1.170 INCHES MAXIMUM |
| OVERALL LENGTH | 3.410 INCHES NOMINAL |
| MEASUREMENT RANGE | +0.0 TO 15.0 POUNDS PRESSURE PER SQUARE INCH |
| MECHANICAL CONNECTION QUANTITY | 2 |
| MECHANICAL CONNECTION SIZE | 0.500-20UNJF-3A |
| MECHANICAL CONNECTION TYPE | FITTING END |
| MOUNTING DEVICE QUANTITY | 1 |
| MOUNTING METHOD | CLAMP |
| NONDEFINITIVE SPEC/STD DATA | 1 NUMBER |
| REFERENCE DATA AND LITERATURE | DRAWING 17B2N4009 |
| RELATIONSHIP TO SIMILAR EQUIPMENT | NOT INTERCHANGEABLE WITH 6685-01-387-5489 & 6685-01-433-6401 |
| SPECIAL FEATURES | MEASUREMENT RANGE 0 TO 15 PSID (DIFFERENTIAL PRESSURE); 0PSID = 0.5VDC, 15PSID = 5VDC |
| SPECIFICATION/STANDARD DATA | 17B2N4009 MANUFACTURERS SPECIFICATION CONTROL |
| USAGE DESIGN | DIFFERENTIAL PRESSURE TRANSMITTER; SENSES THE TRIM AIR PRESSURE RELATIVE TO CABIN PRESSURE. THE OUTPUT SIGNAL SHALL BE CONDITIONED BY THE ASSOCIATED ECS CONTROLLER & USED TO DETECT FAULTY TRIM AIR REGULATOR |
| VOLTAGE RATING | 0.5 VOLTS MINIMUM AND 5.0 VOLTS MAXIMUM OUTPUT |
| VOLTAGE RATING | 10.1 VOLTS NOMINAL INPUT |