National Stock Number: 6680-00-909-5404
Federal Supply Class: 6680
National Item Identification Number: 009095404
Description: METER,FLUID FLOW INDICATING,DIFF
Detail: An instrument designed to measure the rate of flow of a fluid through a pipeline, based on the exact relation which differential pressure bears to fluid velocity, and this measurement indicated on a graduated scale by a pointer directly connected to a mercury or oil sealed bell or a bellows. It may or may not have a totalizing integrator register built in. Excludes: METER, FLOW RATE INDICATING; METER, FLUID FLOW INDICATING, ELECTROMAGNETIC; and METER, FLUID FLOW INDICATING, ULTRASONIC.
|
Manufacturer Information:
| 07BCXXX0100A4CXAXX01 | 05991 | CAMERON ENERGY SERVICES CORP. | | 07CBXXX0100A4CXAXX01 | 05991 | CAMERON ENERGY SERVICES CORP. | | 2270-100INWTR | 05991 | CAMERON ENERGY SERVICES CORP. | | 227A0100I4BR | 05991 | CAMERON ENERGY SERVICES CORP. |
|
Techincal Specification:
| PRESSURE TYPE | LOW OR HIGH | | PROPRIETARY CHARACTERISTICS | PACS | | MOUNTING TYPE | FLUSH | | OUTLET CONNECTION SIZE | 7/16 IN. 20 THD UNF | | SPECIAL FEATURES | 6.000 IN. DIA BLANK WHITE DIAL; RED SET POINTER | | TOTALIZING INTEGRATOR REGISTER | NOT INCLUDED | | DEPTH | 4.656 INCHES NOMINAL | | DIAMETER | 6.500 INCHES NOMINAL | | ACCESSORY COMPONENTS AND QUANTITY | 2.000 IN. BERYLLIUM COPPER SENSOR W/COPPER-NICKEL HOUSING,1 | | CASE MATERIAL | ALUMINUM, CAST | | CASE SHAPE | ROUND | | CRITICALITY CODE JUSTIFICATION | CPYY AND AKYD AND FEAT | | MAXIMUM DIFFERENTIAL PRESSURE | 100.0 IN. OF WATER COLUMN | | III MEDIA FOR WHICH DESIGNED | LIQUID | | INLET CONNECTION SIZE | 7/16 IN. 20 THD UNF |
|
|