| ACTUATION METHOD | TURBINE |
| INLET CONNECTION SIZE | 2.000 IN. IPS |
| INLET CONNECTION TYPE | THREADED |
| INLET THREAD SERIES DESIGNATOR | NPT |
| INSTALLATION LOCATION | LEFT HAND SIDE OR RIGHT HAND SIDE |
| LIQUID FLOW RATE | 65000.0 POUNDS PER HOUR NOMINAL |
| OUTLET THREAD DIRECTION | RIGHT-HAND |
| OUTLET THREAD SERIES DESIGNATOR | NPT |
| OUTLET CONNECTION SIZE | 2.000 IN. IPS |
| OUTLET CONNECTION TYPE | THREADED |
| MATERIAL | STEEL CORROSION RESISTING BODY |
| MEDIA FOR WHICH DESIGNED | JET FUELS |
| OPERATING PRESSURE | 2000.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM |
| REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AS DIFFERENTIATED BY SPECIAL FEATURES |
| SPECIAL FEATURES | OVERALL LG 8.938 IN.; FREQUENCY OF PICKUP 600.0 HZ AT 65000 PHR; SERIAL NO. 7006A3648A1 THRU 4 |
| STRAIGHTENING VANE | PROVIDED |
| THREAD DIRECTION | RIGHT-HAND INLET |