National Stock Number: 6680-00-269-8323
Federal Supply Class: 6680
National Item Identification Number: 002698323
Description: METER,FLUID FLOW INDICATING,DIFF
Detail: An instrument designed to measure the rate of flow of a fluid through a pipeline, based on the exact relation which differential pressure bears to fluid velocity, and this measurement indicated on a graduated scale by a pointer directly connected to a mercury or oil sealed bell or a bellows. It may or may not have a totalizing integrator register built in. Excludes: METER, FLOW RATE INDICATING; METER, FLUID FLOW INDICATING, ELECTROMAGNETIC; and METER, FLUID FLOW INDICATING, ULTRASONIC.
|
Manufacturer Information:
| 06BC1000XXXA4CXAXX01 | 05991 | CAMERON ENERGY SERVICES CORP. | | 73728-15X1-33-3 | 96169 | ELECTRIC BOAT CORPORATION | | R226A100I4BR0X | 05991 | CAMERON ENERGY SERVICES CORP. | | R226A100I4BROX | 05991 | CAMERON ENERGY SERVICES CORP. | | 73728-15X1-33-4 | 96169 | ELECTRIC BOAT CORPORATION | | 73728-15X1-33-5 | 96169 | ELECTRIC BOAT CORPORATION |
|
Techincal Specification:
| ACCESSORY COMPONENTS AND QUANTITY | 2.000 IN. BERYLLIUM COPPER SENSOR W/COPPER-NICKEL HOUSING,1 | | CASE SHAPE | ROUND | | CRITICALITY CODE JUSTIFICATION | CPYY AND FEAT | | DEPTH | 4.656 INCHES NOMINAL | | DIAMETER | 3.125 INCHES NOMINAL | | INLET CONNECTION SIZE | 7/16 IN. 20 THD UNF | | OUTLET CONNECTION SIZE | 7/16 IN. 20 THDUNF | | MATERIAL | ALUMINUM CASE | | MAXIMUM DIFFERENTIAL PRESSURE | 100.0 IN. OF WATER COLUMN | | MEDIA FOR WHICH DESIGNED | WATER | | SPECIAL FEATURES | 3.000 IN. BLANK WHITE DIAL; RED SET POINTER | | PRESSURE TYPE | HIGH | | TOTALIZING INTEGRATOR REGISTER | NOT INCLUDED |
|
|