National Stock Number: 6625-01-406-3706
Federal Supply Class: 6625
National Item Identification Number: 014063706
Description: ANALYZER,DIGITAL DATA,ELECTRONIC
Detail: AN INSTRUMENT DESIGNED TO RECEIVE AND PROCESS DIGITAL SIGNALS FROM ASSOCIATED COMPONENTS IN ORDER TO PERFORM ANALYSIS OF LOGIC STATES, TIMING FUNCTIONS AND MICROPROCESSOR CONTROL. MAY INCLUDE A DISPLAY SCREEN AND/OR TRIGGERING CAPABILITIES.
|
Manufacturer Information:
| 1791-9707 | 24655 | GENRAD INC | | 6625-0807 | 98750 | SAN ANTONIO AIR LOGISTICS CENTER | | A-A-58042 | 58536 | FEDERAL COMMERCIAL ITEM DESCRIPTION PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC | | 94LDAK-67.2-6625-0807 | 98750 | SAN ANTONIO AIR LOGISTICS CENTER | | 94LDAK-67.2-6625-0807 | 98752 | WARNER ROBINS AIR LOGISTICS CENTER | | 6625-0807 | 98752 | WARNER ROBINS AIR LOGISTICS CENTER | | CID6625-0828 | 98750 | SAN ANTONIO AIR LOGISTICS CENTER | | PD-87-MMTD-0067 | 98750 | SAN ANTONIO AIR LOGISTICS CENTER | | SA-ALC-MME-PD418A | 98750 | SAN ANTONIO AIR LOGISTICS CENTER | | SA-ALC-MME-PD418A | 98752 | WARNER ROBINS AIR LOGISTICS CENTER | | PD-87-MMTD-0067 | 98752 | WARNER ROBINS AIR LOGISTICS CENTER | | CID6625-0828 | 98752 | WARNER ROBINS AIR LOGISTICS CENTER |
|
Techincal Specification:
| ELECTRICAL POWER SOURCE RELATIONSHIP | ALTERNATE OPERATING | | AC VOLTAGE RATING | 110.0 VOLTS MINIMUM AND 220.0 VOLTS MAXIMUM LOCATION NOT OTHERWISE SPECIFIED | | FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM LOCATION NOT OTHERWISE SPECIFIED | | FUNCTIONAL DESCRIPTION | LOGIC ANALYSIS | | INDICATOR TYPE | CATHODE RAY TUBE | | OVERALL HEIGHT | 9.000 INCHES NOMINAL | | OVERALL LENGTH | 17.000 INCHES NOMINAL | | OVERALL WIDTH | 15.000 INCHES NOMINAL | | SPECIAL FEATURES | MINIMUM 32 DATA CHANNEL INPUTS; OPERATES FROM INTERNAL (ASYNCHRONOUSLY TO EVENTS IN UUT) AND EXTERNAL (SYNCHRONOUS) CLOCKS; 2 CLOCK QUALIFIER INPUTS WHICH CAN BE LOGICALLY COMBINED TO QUALIFY DATA ACQUISITION IN SYNCHRO OPERATION; DATA INPUTS SAMPLES ASYNCHRONOUSLY AT 100 MEGA SAMPLES PER SEC AND SYNCHRONOUSLY AT UP TO 25 MEGA SAMPLES PER SEC; CRT DISPLAY; LOGIC THRESHOLD SELECTION ACCURACY GREATER THAN PORM 5PCT OF THRESHOLD PORM 5 PCT OF TOTAL VARIABLE VOLTAGE RANGE; MINIMUM DATA SET UP TIME LESS THAN 12 NSEC BEFORE ACTIVE CLOCK TRANSITION; MINIMUM DATA HOLD TIME LESS THAN 2 NSEC; WIDE RANGE MICROPROCESSOR AND BUS SUPPORT OPTIONS; INTEGRATED STATE/TIMING TRIGGER RESOURCES; GLITCH CAPTURE DOWN TO 3 NSECS; SIMULTANEOUS 200 MHZ TIMING/50 MHZ STATE ON ALL CHANNELS; INCLUDES PROBES, LEADS, POWER CORD, & OPERATION MANUALS | | UNPACKAGED UNIT WEIGHT | 30.000 POUNDS |
|
|