| INSTALLATION DESIGN | BENCH |
| INDICATOR TYPE | DIGITAL DISPLAY |
| DISPLAY TYPE | LIQUID CRYSTAL |
| DISPLAY DIGIT QUANTITY | 5 |
| MEASUREMENT RANGE | 1.9 TO 19.9 AMPERES, DC SINGLE INDICATOR SINGLE RANGE |
| ACCURACY RATING | PORM 1 PCT FS PORM 2 DIGITS SINGLE INDICATOR SINGLE RANGE |
| DISPLAY COLOR | RED SINGLE INDICATOR SINGLE RANGE |
| BACKGROUND COLOR | BLACK SINGLE INDICATOR SINGLE RANGE |
| CIRCUIT ATTACHMENT METHOD AND QUANTITY | 4 CONNECTOR, PLUG |
| POWER SOURCE | INTERNAL |
| CIRCUIT CURRENT FOR WHICH DESIGNED | DC |
| OPERATING VOLTAGE RATING IN VOLTS | 7.5 DC MINIMUM AND |
| 15.0 DC MAXIMUM |
| STYLE DESIGNATOR | PORTABLE W/TILT VIEW HANDLE |
| OVERALL DEPTH | 7.500 INCHES NOMINAL |
| OVERALL HEIGHT | 4.500 INCHES NOMINAL |
| OVERALL WIDTH | 13.500 INCHES NOMINAL |
| CIRCUIT CONSTRUCTION TYPE | ELECTRONIC, SOLID STATE |
| NUCLEAR HARDNESS CRITICAL FEATURE | NONHARDENED |
| FEATURES PROVIDED | PORTABLE |
| SPECIAL FEATURES | MEASURES AC,FWDC,OR HWDC CURRENTS IN MEAN AVERAGE,TRUE RMS OR PEAK FROM 199 TO 19999 AMPERES; MEASURES DURATION TIMING OF CURRENT FLOW FROM 0.06 TO 19.99 SEC.(DURATION METER); HAS AUTO HOLD FOR STORING LAST READING INDEFINITELY WITH AUTOMATIC RESET & UPDATE AFTER EACH MEASUREMENT OR MAY BE OPERATED IN MANUAL MODE;REQUIRES 8 EA AA TYPE ALKALINE OR NI-CAD BATTRIES;OPERATING TEMP. 40 TO 115 DEG F.;STORAGE TEMP.32 TO 135 DEG. F.;MOUNTED IN PORTABLE CARRYING CASE WITH CARRYING HANDLE |