| INSTALLATION DESIGN | PANEL |
| INDICATOR TYPE | DIAL W/POINTER |
| MEASUREMENT RANGE | 0.0 TO 1.0 AMPERES SINGLE INDICATOR 1ST RANGE |
| 0.0 TO 500.0 KILOVOLTS SINGLE INDICATOR 2ND RANGE |
| ACCURACY IN PERCENT | -2.0 TO 2.0 AT FULL SCALE SINGLE INDICATOR ALL RANGES |
| POINTER COLOR | BLACK SINGLE INDICATOR ALL RANGES |
| DIAL SCALE MARKING COLOR | BLACK SINGLE INDICATOR ALL RANGES |
| BACKGROUND COLOR | WHITE SINGLE INDICATOR ALL RANGES |
| MOVEMENT TYPE | MOVING COIL, PERMANENT MAGNET |
| MOVEMENT SUSPENSION METHOD | JEWEL PIVOT BASE |
| CIRCUIT ATTACHMENT METHOD AND QUANTITY | 2 THREADED STUD |
| SCALE SELECTION METHOD | TERMINAL |
| POWER SOURCE | EXTERNAL |
| CIRCUIT CURRENT FOR WHICH DESIGNED | DC |
| STYLE DESIGNATOR | RECTANGULAR FLUSH MTG |
| METER BODY DIAMETER BEHIND MOUNTING FLANGE | 2.180 INCHES NOMINAL |
| METER DEPTH BEHIND MOUNTING FLANGE | 1.310 INCHES NOMINAL |
| OVERALL HEIGHT | 2.900 INCHES NOMINAL |
| OVERALL LENGTH | 2.190 INCHES NOMINAL |
| OVERALL WIDTH | 4.500 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED STUD |
| MOUNTING STUD DIAMETER | 0.138 INCHES NOMINAL |
| MOUNTING STUD LENGTH | 0.680 INCHES NOMINAL |
| MOUNTING ARRANGEMENT STYLE | TWO HOLE/STUD |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 3.500 INCHES NOMINAL |
| NUCLEAR HARDNESS CRITICAL FEATURE | NONHARDENED |
| FEATURES PROVIDED | ZERO ADJUSTER |
| FSC APPLICATION DATA | TEST SET,ELECT. EQUIP. |