6150-01-097-5734 CABLE ASSEMBLY,SPECIAL PURPOSE,E Index 6625-01-097-5736 ANALYZER,SPECTRUM

National Stock Number:
6625-01-097-5735

Federal Supply Class:
6625

National Item Identification Number:
010975735

Description:
WATTMETER

Detail:
An instrument which measures one or more different electrical power quantities (such as decibels and watts), and is calibrated using watts. The power measurement and/or calibration may be displayed in multiples and/or submultiples thereof on a dial and/or digital readout display. For items designed to measure radio frequency power see TEST SET, ELECTRICAL POWER and METER, MULTIPLE SCALE. Excludes: AMMETER; FREQUENCY METER; MULTIMETER; VOLTMETER.


Manufacturer Information:
2503-2360336YOKOGAWA CORPORATION OF AMERICA
2503-23S4164YOKOGAWA ELECTRIC WORKS LTD


Techincal Specification:
ACCURACY RATING0.1 PCT SINGLE INDICATOR SINGLE RANGE
CIRCUIT ATTACHMENT METHOD AND QUANTITY3 CONNECTOR, PLUG
CIRCUIT CURRENT FOR WHICH DESIGNEDAC
DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS2200.0
DISPLAY COLORGREEN SINGLE INDICATOR SINGLE RANGE
DISPLAY DIGIT QUANTITY4-1/2
DISPLAY TYPELIGHT EMITTING DIODE (L.E.D.).
FREQUENCY RATING50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM
FREQUENCY RESPONSE RANGE+0.000 TO 1.200 KILOHERTZ
INDICATOR TYPEDIGITAL DISPLAY
INSTALLATION DESIGNBENCH
OVERALL LENGTH17.250 INCHES NOMINAL
OVERALL WIDTH14.375 INCHES NOMINAL
MEASUREMENT RANGE+0.0 TO 30.0 AMPERES SINGLE INDICATOR SECOND RANGE
MEASUREMENT RANGE+0.0 TO 36.0 KILOWATTS SINGLE INDICATOR THIRD RANGE
MEASUREMENT RANGE+3.0 TO 600.0 VOLTS SINGLE INDICATOR FIRST RANGE
NUCLEAR HARDNESS CRITICAL FEATURENONHARDENED
OPERATING VOLTAGE RATING IN VOLTS100.0 AC MINIMUM AND 230.0 AC MAXIMUM
OVERALL HEIGHT5.875 INCHES NOMINAL
POWER SOURCEEXTERNAL
SPECIAL FEATURESVOLTAGE FREQUENCY RESPONSE DC AND25 HZ TO 2 KILOHZ; CURRENT FREQUENCY RESPONSE 25 HZ TO 2 KILOHZ; POWER FREQUENCY RESPONSE 40 HZ TO 1.2 KILOHZ; ACCURACY VOLTAGE/CURRENT PORM 0.1 PCT OF OF READING PLUS 0.02 PCT OF RANGE PLUS1 DIGIT FOR 50 TO 400 HZ,PORM 0.2 PCTOF READING PLUS 0.03 PCT OF RANGE PLUS1 DIGIT FOR DC,25 TO 50 AND 400 HZ TO2 KILOHZ; POWER ACCURACY PORM 0.1 PCT OF READING PLUS 0.02 PCT OR RANGE PLUS1 DIGIT FOR 60 TO 400 HZ,PORM 0.2 PCTOF READING PLUS 0.03 PCT OF RANGE PLUS1 DIGIT FOR 40 TO 50 AND 400 HZ TO 1.2KILOHZ
STYLE DESIGNATORRECTANGULAR OR SQUARE
SUPPLEMENTARY FEATURES6 VOLTAGE RANGES 3,10,30,100,300,600V; 7 CURRENT RANGES 100,300,1,000 MILLAA,3,6,10,30A; POWER RANGE 600MILLAW TO 36KILOW


Click here to Register for Free 30-day Trial