| INSTALLATION DESIGN | PANEL |
| PANEL FOR WHICH DESIGNED | NONMAGNETIC |
| INDICATOR TYPE | DIAL W/POINTER |
| SCALE MARKING | DDM;UPPER RANGE: -.25; -.2; -.15; -.1; -.05; 0; .05; .1; .15; .2; .25; LOWER RANGE: -.5; -.4; -.3; -.2; -.1; 0; 1;2; 3; 4; 5 |
| ACCURACY IN PERCENT | -1.0 TO 1.0 AT 1/2 SCALE SINGLE INDICATOR ALL RANGES |
| SCALE GRADUATION TYPE | LINEAR SINGLE INDICATOR ALL RANGES |
| SCALE DIVISION QUANTITY | 50 SINGLE INDICATOR ALL RANGES |
| POINTER COLOR | BLACK SINGLE INDICATOR ALL RANGES |
| DIAL SCALE MARKING COLOR | BLACK SINGLE INDICATOR ALL RANGES |
| BACKGROUND COLOR | WHITE SINGLE INDICATOR ALL RANGES |
| MOVEMENT TYPE | MOVING COIL, PERMANENT MAGNET |
| MOVEMENT SUSPENSION METHOD | JEWEL PIVOT BASE |
| FREQUENCY RESPONSE RANGE | 90.000 TO 150.000 HERTZ |
| CIRCUIT ATTACHMENT METHOD AND QUANTITY | 2 THREADED STUD |
| SENSITIVITY RATING | 50.0 MICROAMPERES |
| CIRCUIT CURRENT FOR WHICH DESIGNED | AC |
| STYLE DESIGNATOR | RECTANGULAR FLUSH MTG |
| METER BODY DIAMETER BEHIND MOUNTING FLANGE | 2.140 INCHES NOMINAL |
| METER DEPTH BEHIND MOUNTING FLANGE | 1.300 INCHES NOMINAL |
| OVERALL HEIGHT | 2.270 INCHES NOMINAL |
| OVERALL LENGTH | 2.200 INCHES NOMINAL |
| OVERALL WIDTH | 2.990 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD |
| MOUNTING STUD DIAMETER | 0.112 INCHES NOMINAL |
| MOUNTING STUD LENGTH | 0.500 INCHES NOMINAL |
| MOUNTING ARRANGEMENT STYLE | FOUR HOLE/STUD RECTANGULAR/SQUARE |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.880 INCHES NOMINAL |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.880 INCHES NOMINAL |
| MATERIAL | PLASTIC |
| NUCLEAR HARDNESS CRITICAL FEATURE | NONHARDENED |
| ENVIRONMENTAL PROTECTION | COLD RESISTANT AND |
| HEAT RESISTANT AND |
| SHOCK RESISTANT AND |
| VIBRATION RESISTANT |
| SPECIAL MARKINGS | -.155 AND .155 W/LINE TO SCALE; 90 HZ LEFT END; 150 HZ RIGHT END |
| FEATURES PROVIDED | MIRROR SCALE AND |
| ZERO ADJUSTER |
| SPECIAL FEATURES | 700 OHMS RESISTANCE |
| SPECIAL TEST FEATURES | MEETS MIL-T-21200,MIL-T-945 AND USA STANDARD C-39.1 ENVIRONMENTAL REQUIREMENTS |
| FSC APPLICATION DATA | TEST SET,ELECT. EQUIP. |