| ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| ENCLOSURE FEATURE | MULTIPLE ITEM IN SELF-CONTAINED COMBINATION CASE W/O CARRYING CASE |
| AC VOLTAGE RATING | 115.0 VOLTS NOMINAL FIRST OPERATING POWER RQMT |
| CUBIC MEASURE | 4370.00 CUBIC INCHES |
| DEPTH | 19.000 INCHES NOMINAL |
| FUNCTIONAL DESCRIPTION | USED TO TEST RADAR POWER,FREQ.,PULSE REPETITION FREQ.,AND RANGE TRACKING CAPABILITIES; TESTS CAN BE PERFORMED IN LABORATORY,SHOP OR FLIGHTLINE ENVIRONMENT |
| ENTRY DATE | 80-10-01 |
| FREQUENCY RATING | 60.0 HERTZ MINIMUM AND 400.0 HERTZ MAXIMUM FIRST OPERATING POWER RQMT |
| FUNCTIONAL CLASSIFICATION | AA-9.1 |
| HEIGHT | 11.500 INCHES NOMINAL |
| LENGTH | 20.000 INCHES NOMINAL |
| MAJOR COMPONENTS | POWER CABLE; MICROWAVE CABLE; BNC CABLE |
| PHASE | SINGLE FIRST OPERATING POWER RQMT |
| REFERENCE DATA AND LITERATURE | T.O. 33D7-44-225-4 |
| RELATIONSHIP TO SIMILAR EQUIPMENT | REPLACES AN/GPM-25,AN/UPM-10( ),AN/UPM-11( ),TS-147( ),TS-488( ) |
| TEST TYPE FOR WHICH DESIGNED | X-BAND TRANSMITTER TESTING; X-BAND RECEIVER TESTING; X-BAND SIGNAL GENERATOR |
| TYPE/MODEL DESIGNATION | AN/UPM-145 |