4320-00-999-5363 PUMP UNIT,RECIPROCATING Index 7125-00-999-5365 SHELVING KIT

National Stock Number:
6625-00-999-5364

Federal Supply Class:
6625

National Item Identification Number:
009995364

Description:
FREQUENCY MEASURING SET

Detail:
A fixed number of components and/or items, not all having the same basic name, for the passive detection and direct display of the frequency being measured. May exclude certain operating components supplied separately or already present at the point of usuage. For items using the heterodyne principle of frequency determination, see FREQUENCY METER. See also METER, ELECTRICAL FREQUENCY. For items using the absorption principle of frequency determination, see WAVEMETER.


Manufacturer Information:
5245L-E141LQK8KEYSIGHT TECHNOLOGIES, INC.
5245L-E141MY97AGILENT TECHNOLOGIES, INC.
E14-5245L28480HEWLETT-PACKARD COMPANY
5245L-E147ZXR5KEYSIGHT TECHNOLOGIES INC


Techincal Specification:
ACCESSORY COMPONENT NAMEFREQUENCY CONVERTER; TIME INTERVAL UNIT
ACCESSORY COMPONENT QUANTITY2
AC VOLTAGE RATING115.0 VOLTS NOMINAL FIRST ALTERNATE OPERATING POWER RQMT
AC VOLTAGE RATING230.0 VOLTS NOMINAL SECOND ALTERNATE OPERATING POWER RQMT
ACCESSORY CONTROLLING AGENCYHEWLETT-PACKARD CO
ACCESSORY IDENTIFYING NUMBER5253BJAC5262A MODEL NO.
FREQUENCY BAND QUANTITY1
FREQUENCY MEASUREMENT OPERATING TEMP RANGE-20.0 TO 65.0 CELSIUS
FREQUENCY MEASUREMENT RATING0.0 MEGAHERTZ MINIMUM AND 512.0 MEGAHERTZ MAXIMUM
FREQUENCY RATING60.0 HERTZ NOMINAL FIRST ALTERNATE OPERATING POWER RQMT
FREQUENCY RATING60.0 HERTZ NOMINAL SECOND ALTERNATE OPERATING POWER RQMT
INDICATOR TYPEDECADE COUNTER
SPECIAL FEATURES5-1/4 IN. BY 16-1/2 IN. BY 16-3/4 IN. O/A DIM. W/CASE
PHASESINGLE FIRST ALTERNATE OPERATING POWER RQMT
PHASESINGLE SECOND ALTERNATE OPERATING POWER RQMT