| INSTALLATION DESIGN | PANEL |
| INDICATOR TYPE | DIAL W/POINTER |
| MEASUREMENT RANGE | 0.0 TO 100.0 KILOWATTS SINGLE INDICATOR SINGLE RANGE |
| ACCURACY IN PERCENT | -2.000 TO 2.000 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE |
| DIAL SCALE MARKING COLOR | BLACK SINGLE INDICATOR SINGLE RANGE |
| BACKGROUND COLOR | WHITE SINGLE INDICATOR SINGLE RANGE |
| CIRCUIT ATTACHMENT METHOD AND QUANTITY | 2 EYELET |
| CIRCUIT CURRENT FOR WHICH DESIGNED | AC |
| STYLE DESIGNATOR | ROUND FLUSH MTG |
| METER BODY DIAMETER BEHIND MOUNTING FLANGE | 2.620 INCHES MAXIMUM |
| METER DEPTH BEHIND MOUNTING FLANGE | 2.160 INCHES MAXIMUM |
| OVERALL DIAMETER | 3.580 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 FLANGE |
| MOUNTING ARRANGEMENT STYLE | THREE HOLE/STUD BOLT CIRCLE |
| MOUNTING BOLT CIRCLE DIAMETER | 3.150 INCHES NOMINAL |
| FEATURES PROVIDED | RECTIFIER CIRCUIT |
| SPECIAL FEATURES | 3 MTG HOLE/STUDS 0.150 IN. DIA |
| FSC APPLICATION DATA | TEST SETS,ELECTRONIC SYSTEMS,EXCEPT SPECIALLY DESIGNED |