| INSTALLATION DESIGN | PANEL |
| MEASUREMENT RANGE | 105.0 TO 125.0 VOLTS, AC SINGLE INDICATOR SINGLE RANGE |
| ACCURACY IN PERCENT | -0.6 TO 0.6 AT FULL SCALE SINGLE INDICATOR ALL RANGES |
| SCALE DIVISION QUANTITY | 40 SINGLE INDICATOR SINGLE RANGE |
| DIAL SCALE MARKING COLOR | BLACK SINGLE INDICATOR SINGLE RANGE |
| BACKGROUND COLOR | WHITE SINGLE INDICATOR SINGLE RANGE |
| FREQUENCY RESPONSE RANGE | 55.000 TO 500.000 HERTZ |
| CIRCUIT ATTACHMENT METHOD AND QUANTITY | 2 SOLDER STUD |
| SENSITIVITY RATING | 2.0 MICROAMPERES |
| SCALE SELECTION METHOD | TERMINAL |
| CIRCUIT CURRENT FOR WHICH DESIGNED | AC |
| STYLE DESIGNATOR | ROUND FLUSH MTG |
| METER BODY DIAMETER BEHIND MOUNTING FLANGE | 2.656 INCHES NOMINAL |
| METER DEPTH BEHIND MOUNTING FLANGE | 3.593 INCHES NOMINAL |
| OVERALL DIAMETER | 3.510 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 3 UNTHREADED HOLE |
| MOUNTING HOLE DIAMETER | 0.150 INCHES NOMINAL |
| MOUNTING ARRANGEMENT STYLE | THREE HOLE/STUD BOLT CIRCLE |
| MOUNTING BOLT CIRCLE DIAMETER | 3.156 INCHES NOMINAL |
| THE MANUFACTURERS DATA | |
| MANUFACTURERS CODE | 16902 |
| DESIGN CONTROL REFERENCE | 026-3106-3 |