| ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| ENCLOSURE FEATURE | SINGLE ITEM W/CARRYING CASE |
| AC VOLTAGE RATING | 115.0 VOLTS NOMINAL LOCATION NOT OTHERWISE SPECIFIED |
| ENTRY DATE | 78-9-1 |
| FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM LOCATION NOT OTHERWISE SPECIFIED |
| FUNCTIONAL CLASSIFICATION | AA-9.1 |
| FUNCTIONAL DESCRIPTION | SIMULATES RADAR TARGETS WHICH MAYBE CONTROLLED IN RANGE,RATE AND ACCELERATION AND CAN BE USED FOR MALFUNCTION ISOLATION AND CALIBRATION OF RADAR SETS AT ORGANIZATIONAL AND INTERMEDIATELEVELS OF MAINTENANCE |
| HEIGHT | 12.500 INCHES NOMINAL |
| LENGTH | 16.938 INCHES NOMINAL |
| MAJOR COMPONENTS | CABLE ASSY POWER ELECTRICAL,CABLE ASSY RADIO FREQUENCY,CABLE ASSY SPECIAL PURPOSE ELECTRICAL,COVER-TEST SET,TEST SET RADAR |
| MATERIAL | ALUMINUM CARRYING CASE |
| PHASE | SINGLE LOCATION NOT OTHERWISE SPECIFIED |
| REFERENCE DATA AND LITERATURE | NAVAIR 16-30UPM109-1 |
| SPECIAL FEATURES | CAN BE OPERATED IN A HORIZONTAL OR VERTICAL PLANE |
| WIDTH | 21.938 INCHES NOMINAL |
| TEST TYPE FOR WHICH DESIGNED | CALIBRATION |
| TYPE/MODEL DESIGNATION | AN/UPM-109 |