| INSTALLATION DESIGN | PANEL |
| INDICATOR TYPE | DIAL W/POINTER |
| MEASUREMENT RANGE | 0.0 TO 115.0 AMPERES, AC SINGLE INDICATOR SINGLE RANGE |
| ACCURACY IN PERCENT | -2.0 TO 2.0 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE |
| SCALE GRADUATION TYPE | LINEAR SINGLE INDICATOR SINGLE RANGE |
| SCALE DIVISION QUANTITY | 24 SINGLE INDICATOR SINGLE RANGE |
| POINTER COLOR | YELLOW, FLUORESCENT SINGLE INDICATOR SINGLE RANGE |
| DIAL SCALE MARKING COLOR | YELLOW, FLUORESCENT SINGLE INDICATOR SINGLE RANGE |
| BACKGROUND COLOR | BLACK SINGLE INDICATOR SINGLE RANGE |
| MOVEMENT TYPE | MOVING IRON VANE |
| MOVEMENT SUSPENSION METHOD | TAUT BAND |
| CIRCUIT ATTACHMENT METHOD AND QUANTITY | 2 THREADED STUD |
| SENSITIVITY RATING | 5.0 MILLIAMPERES |
| DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 3000.0 |
| POWER SOURCE | EXTERNAL |
| CIRCUIT CURRENT FOR WHICH DESIGNED | AC |
| PHASE | SINGLE |
| STYLE DESIGNATOR | RECTANGULAR FLUSH MTG |
| METER BODY DIAMETER BEHIND MOUNTING FLANGE | 2.078 INCHES NOMINAL |
| METER DEPTH BEHIND MOUNTING FLANGE | 2.125 INCHES MAXIMUM |
| OVERALL HEIGHT | 2.380 INCHES NOMINAL |
| OVERALL LENGTH | 3.350 INCHES MAXIMUM |
| OVERALL WIDTH | 2.380 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
| MOUNTING HOLE DIAMETER | 0.218 INCHES NOMINAL |
| MOUNTING ARRANGEMENT STYLE | FOUR HOLE/STUD RECTANGULAR/SQUARE |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.875 INCHES NOMINAL |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.875 INCHES NOMINAL |
| PANEL FOR WHICH DESIGNED | MAGNETIC OR |
| NONMAGNETIC |
| CIRCUIT CONSTRUCTION TYPE | NONELECTRONIC |
| MATERIAL | STEEL |
| SURFACE TREATMENT | ENAMEL |
| NUCLEAR HARDNESS CRITICAL FEATURE | NONHARDENED |
| ENVIRONMENTAL PROTECTION | SHOCK RESISTANT AND |
| VIBRATION RESISTANT |
| FURNISHED ITEMS AND QUANTITY | TERM. HDW 2 |
| FEATURES PROVIDED | ZERO ADJUSTER |
| SPECIAL FEATURES | RUGGEDIZED |
| SPECIAL TEST FEATURES | CONFORMS TO MIL-I-8374 AND MS335480 |
| SUPPLEMENTARY FEATURES | USED W/EXTERNAL CURRENT TRANSFORMER |
| FSC APPLICATION DATA | TEST SET,ELECT. EQUIP. |