| INSTALLATION DESIGN | PANEL |
| MEASUREMENT RANGE | 0.0 TO 150.0 AMPERES, AC SINGLE INDICATOR 1ST RANGE |
| 0.0 TO 300.0 AMPERES, AC SINGLE INDICATOR 2ND RANGE |
| ACCURACY IN PERCENT | -2.0 TO 2.0 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE |
| DIAL SCALE MARKING COLOR | BLACK SINGLE INDICATOR ALL RANGES |
| BACKGROUND COLOR | WHITE SINGLE INDICATOR ALL RANGES |
| CIRCUIT ATTACHMENT METHOD AND QUANTITY | 2 THREADED STUD |
| SENSITIVITY RATING | 50.0 MILLIVOLTS |
| CIRCUIT CURRENT FOR WHICH DESIGNED | AC |
| STYLE DESIGNATOR | ROUND FLUSH MTG |
| METER BODY DIAMETER BEHIND MOUNTING FLANGE | 2.800 INCHES MAXIMUM |
| METER DEPTH BEHIND MOUNTING FLANGE | 2.010 INCHES MINIMUM |
| OVERALL DIAMETER | 3.499 INCHES MINIMUM AND |
| 3.501 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 FLANGE |
| MOUNTING ARRANGEMENT STYLE | THREE HOLE/STUD BOLT CIRCLE |
| MOUNTING BOLT CIRCLE DIAMETER | 3.153 INCHES MINIMUM AND |
| 3.167 INCHES MAXIMUM |
| MATERIAL | PLASTIC |
| SPECIAL FEATURES | MTG HOLE/STUD 0.143 MIN AND 0.157 MAX DIA |