| INSTALLATION DESIGN | PANEL |
| MEASUREMENT RANGE | 0.0 TO 100.0 MILLIAMPERES, DC SINGLE INDICATOR SINGLE RANGE |
| ACCURACY IN PERCENT | -1.0 TO 1.0 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE |
| SCALE DIVISION QUANTITY | 100 SINGLE INDICATOR SINGLE RANGE |
| DIAL SCALE MARKING COLOR | BLACK SINGLE INDICATOR SINGLE RANGE |
| BACKGROUND COLOR | WHITE SINGLE INDICATOR SINGLE RANGE |
| MOVEMENT TYPE | MOVING COIL, PERMANENT MAGNET |
| CIRCUIT ATTACHMENT METHOD AND QUANTITY | 2 SOLDER LUG |
| SCALE SELECTION METHOD | TERMINAL |
| DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 1500.0 |
| CIRCUIT CURRENT FOR WHICH DESIGNED | DC |
| STYLE DESIGNATOR | ROUND FLUSH MTG |
| METER BODY DIAMETER BEHIND MOUNTING FLANGE | 2.800 INCHES NOMINAL |
| METER DEPTH BEHIND MOUNTING FLANGE | 2.000 INCHES NOMINAL |
| OVERALL DIAMETER | 3.400 INCHES MINIMUM AND |
| 3.500 INCHES MAXIMUM |
| OVERALL LENGTH | 2.380 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 3 UNTHREADED HOLE |
| MOUNTING HOLE DIAMETER | 0.140 INCHES MINIMUM AND |
| 0.160 INCHES MAXIMUM |
| MOUNTING ARRANGEMENT STYLE | THREE HOLE/STUD BOLT CIRCLE |
| MOUNTING BOLT CIRCLE DIAMETER | 3.160 INCHES NOMINAL |
| SURFACE TREATMENT | ENAMEL |