| INSTALLATION DESIGN | PANEL |
| PANEL FOR WHICH DESIGNED | MAGNETIC OR |
| NONMAGNETIC |
| INDICATOR TYPE | DIAL W/POINTER |
| SCALE MARKING | UPPER RANGE: TX; 16; 18; 20; 22; 24; 25; 26; 27; 28; 29; CENTER RANGE (REFERENCE): 0; .2; .4; .6; .8; 1.0; LOWER RANGE: LC; 16; 12; 10; 8; 7; 6; 5; 4; 3 |
| ACCURACY IN PERCENT | -2.0 TO 2.0 AT FULL SCALE SINGLE INDICATOR ALL RANGES |
| SCALE GRADUATION TYPE | NONLINEAR SINGLE INDICATOR 1ST RANGE |
| LINEAR SINGLE INDICATOR 2ND RANGE |
| NONLINEAR SINGLE INDICATOR 3RD RANGE |
| SCALE DIVISION QUANTITY | 50 SINGLE INDICATOR 2ND RANGE |
| POINTER COLOR | BLACK SINGLE INDICATOR ALL RANGES |
| DIAL SCALE MARKING COLOR | BLACK SINGLE INDICATOR ALL RANGES |
| BACKGROUND COLOR | WHITE SINGLE INDICATOR ALL RANGES |
| MOVEMENT TYPE | MOVING IRON VANE |
| MOVEMENT SUSPENSION METHOD | TAUT BAND |
| FREQUENCY RESPONSE RANGE | 50.000 TO 430.000 HERTZ |
| CIRCUIT ATTACHMENT METHOD AND QUANTITY | 16 SOLDER PIN |
| DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 3000.0 |
| CIRCUIT CURRENT FOR WHICH DESIGNED | AC |
| OPERATING VOLTAGE RATING IN VOLTS | 115.0 AC NOMINAL |
| FREQUENCY RATING | 60.0 HERTZ NOMINAL |
| PHASE | SINGLE |
| STYLE DESIGNATOR | ROUND FLUSH MTG |
| METER BODY DIAMETER BEHIND MOUNTING FLANGE | 2.820 INCHES NOMINAL |
| METER DEPTH BEHIND MOUNTING FLANGE | 3.941 INCHES NOMINAL |
| OVERALL DIAMETER | 3.510 INCHES MAXIMUM |
| OVERALL LENGTH | 4.641 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 3 UNTHREADED HOLE |
| MOUNTING HOLE DIAMETER | 0.150 INCHES NOMINAL |
| MOUNTING ARRANGEMENT STYLE | THREE HOLE/STUD BOLT CIRCLE |
| MOUNTING BOLT CIRCLE DIAMETER | 3.160 INCHES NOMINAL |
| MATERIAL | STEEL |
| SURFACE TREATMENT | ENAMEL |
| NUCLEAR HARDNESS CRITICAL FEATURE | NONHARDENED |
| ENVIRONMENTAL PROTECTION | SHOCK RESISTANT AND |
| VIBRATION RESISTANT |
| FURNISHED ITEMS AND QUANTITY | MTG HDW 3; GASKET 1 |
| FEATURES PROVIDED | ZERO ADJUSTER |
| SPECIAL FEATURES | RUGGEDIZED |
| SPECIAL TEST FEATURES | CONFORMS TO MIL-M-10304 |
| SUPPLEMENTARY FEATURES | 5000.0 OHMS INPUT RESISTANCE |
| FSC APPLICATION DATA | TEST SET,ELECT. EQUIP. |