5910-00-005-3119 CAPACITOR,FIXED,ELECTROLYTIC Index 5910-00-005-3123 CAPACITOR,FIXED,ELECTROLYTIC

National Stock Number:
6625-00-005-3120

Federal Supply Class:
6625

National Item Identification Number:
000053120

Description:
VOLTMETER

Detail:
An instrument which measures electrical potential and is calibrated in volts or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display.


Manufacturer Information:
204415309JEWELL INSTRUMENTS, LLC DBA MODUTEC USE CAGE CODE 33005 FOR CATALOGING
204433005JEWELL INSTRUMENTS LLC
ER104166-00158474SUPERIOR ELECTRIC HOLDING GROUP LLC
ER104166G158474SUPERIOR ELECTRIC HOLDING GROUP LLC
204465092SOLARTRON ELECTRONICS INC WESTON INSTRUMENTS DIV
4SE00300-1380020NAVAL AIR WARFARE CENTER AIRCRAFT DIVISION CODE 4.8.8.0.0.B BLDG 148-2


Techincal Specification:
INSTALLATION DESIGNPANEL
INDICATOR TYPEDIAL W/POINTER
MEASUREMENT RANGE0.0 TO 150.0 VOLTS, AC SINGLE INDICATOR SINGLE RANGE
ACCURACY IN PERCENT-2.0 TO 2.0 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE
SCALE GRADUATION TYPELINEAR SINGLE INDICATOR SINGLE RANGE
SCALE DIVISION QUANTITY75 SINGLE INDICATOR SINGLE RANGE
POINTER COLORBLACK SINGLE INDICATOR SINGLE RANGE
DIAL SCALE MARKING COLORBLACK SINGLE INDICATOR SINGLE RANGE
BACKGROUND COLORWHITE SINGLE INDICATOR SINGLE RANGE
MOVEMENT TYPEMOVING COIL, PERMANENT MAGNET
MOVEMENT SUSPENSION METHODJEWEL PIVOT BASE
FREQUENCY RESPONSE RANGE25.000 TO 125.000 HERTZ
CIRCUIT ATTACHMENT METHOD AND QUANTITY2 THREADED STUD
POWER SOURCEEXTERNAL
CIRCUIT CURRENT FOR WHICH DESIGNEDAC
STYLE DESIGNATORRECTANGULAR FLUSH MTG
METER BODY DIAMETER BEHIND MOUNTING FLANGE2.760 INCHES MAXIMUM
METER DEPTH BEHIND MOUNTING FLANGE1.150 INCHES MAXIMUM
OVERALL HEIGHT4.220 INCHES MAXIMUM
OVERALL LENGTH1.931 INCHES MAXIMUM
OVERALL WIDTH4.770 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD
MOUNTING STUD DIAMETER0.138 INCHES MINIMUM
MOUNTING STUD LENGTH0.750 INCHES MAXIMUM
MOUNTING ARRANGEMENT STYLEFOUR HOLE/STUD RECTANGULAR/SQUARE
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH4.000 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH3.552 INCHES MINIMUM AND
3.572 INCHES MAXIMUM
MATERIALPLASTIC PHENOL-FORMALDEHYDE
NUCLEAR HARDNESS CRITICAL FEATURENONHARDENED
FEATURES PROVIDEDZERO ADJUSTER
FSC APPLICATION DATATEST SET,ELECT. EQUIP.