ELECTRICAL CONNECTION IDENTIFYING NUMBER | MATES WITH MS27473T18B332S |
ELECTRICAL CONNECTION QUANTITY | 1 |
PART NAME ASSIGNED BY CONTROLLING AGENCY | ALTIMETER,BAROMETRIC PRESSURE,STANDBY, FORMERLY HWAS CALLED ALTIMETER, PRESSURE |
POINTER QUANTITY | 1 |
PROPRIETARY CHARACTERISTICS | PACS |
MECHANICAL CONNECTION QUANTITY | 1 |
MECHANICAL CONNECTION SIZE | STATIC INLET PORT FITTING IAW AN816-4J |
OVERALL DEPTH | 6.990 INCHES NOMINAL |
OVERALL HEIGHT | 3.250 INCHES NOMINAL |
OVERALL WIDTH | 3.250 INCHES NOMINAL |
REFERENCE DATA AND LITERATURE | LOCKHEED DRAWINGS 698056 AND D698056 |
SCALE QUANTITY | 1 AND 1 |
SCALE NAME | ALTITUDE AND BAROMETRIC PRESSURE |
SCALE RANGE | ALTIMETER -1000 FT TO +50,000FT (-305 METERS TO 15,240 |
SPECIAL FEATURES | YELLOW STANDBY FLAG; TWO LIGHTING MODES - NVIS COMPATABLE GREEN A, 5 VOLTS AND WHITE HIGH INTENSITY LIGHT 28 VDC. UNIT AUTOMATICCALY CHANGES TO STANDY UPON LOSS OF SIGNAL FROM THE ARINC BUSS, OR CAN BE MANUALLY SWITCHED TO STANDBY. USER CAN SELECT ENGLISH OR METRIC UNITS (DIAL AND POINTER WILL INDIACTED 0 TO 1000FT OR 0 TO 1000 METERS PER REVOLUTION) |
SUPPLEMENTARY FEATURES | DISPLAYS PRESSURE ALTITUDE IN STANDBY MODE TROUGH USE OF INTERNAL PRESSURE SENSOR. PROVIDES A BAROMETRIC PRESSURE SETTING OUTPUT AND RECEIVES PRESSURE ALTITUDE THROUGH AN ARINC 429 INTERFACE, DISPLAY IN ENGLISH OR METRIC UNITS |