6150-01-662-3601 BUS,CONDUCTOR 6150-01-662-6303 CABLE ASSEMBLY,SPECIAL PURPOSE,E

National Stock Number:
6150-01-662-5900

Federal Supply Class:
6150

National Item Identification Number:
016625900

Description:
LEAD ASSEMBLY,ELECTRICAL


Manufacturer Information:
34000D11421284XB60GENERAL ATOMICS


Techincal Specification:
COLORBLACK FIRST POSITION PRIMARY INSULATION FIFTH CONDUCTOR
COLORBLACK FIRST POSITION PRIMARY INSULATION FIRST CONDUCTOR
COLORBLACK FIRST POSITION PRIMARY INSULATION THIRD CONDUCTOR
COLORWHITE FIRST POSITION PRIMARY INSULATION SIXTH CONDUCTOR
COLORWHITE FIRST POSITION PRIMARY INSULATION FOURTH CONDUCTOR
COLORWHITE FIRST POSITION PRIMARY INSULATION SECOND CONDUCTOR
CONDUCTOR QUANTITY6
CONDUCTOR CROSS-SECTIONAL SHAPETUBULAR BRAID ALL CONDUCTORS
CONDUCTOR FORMSTRANDED ALL CONDUCTORS
INDIVIDUAL CONDUCTOR LENGTH23.0 INCHES NOMINAL SECOND END FIRST CONDUCTOR
INDIVIDUAL CONDUCTOR LENGTH23.0 INCHES NOMINAL SECOND END SECOND CONDUCTOR
INDIVIDUAL CONDUCTOR LENGTH35.0 INCHES NOMINAL SECOND END FOURTH CONDUCTOR
INDIVIDUAL CONDUCTOR LENGTH35.0 INCHES NOMINAL SECOND END THIRD CONDUCTOR
INDIVIDUAL CONDUCTOR LENGTH47.0 INCHES NOMINAL SECOND END FIFTH CONDUCTOR
INDIVIDUAL CONDUCTOR LENGTH47.0 INCHES NOMINAL SECOND END SIXTH CONDUCTOR
OUTSIDE DIAMETER0.065 INCHES MINIMUM AND 0.069 INCHES MAXIMUM ALL CONDUCTORS
PART NAME ASSIGNED BY CONTROLLING AGENCYCABLE ASSEMBLY, INPUT PWR, PPIS SLAVE COOLING UNIT
MATERIALCOPPER CORE CONDUCTOR ALL CONDUCTORS
MATERIALPLASTIC CROSS-LINKED MODIFIED ETHYLENE TETRAFLUOROETHYLENE FIRST POSITION PRIMARY INSULATION FOURTH CONDUCTOR
MATERIALPLASTIC CROSS-LINKED MODIFIED ETHYLENE TETRAFLUOROETHYLENE FIRST POSITION PRIMARY INSULATION SECOND CONDUCTOR
MATERIALPLASTIC CROSS-LINKED MODIFIED ETHYLENE TETRAFLUOROETHYLENE FIRST POSITION PRIMARY INSULATION SIXTH CONDUCTOR
MATERIALPLASTIC ETHYLENE-TETRAFLUOROETHYLENE FIRST POSITION PRIMARY INSULATION FIFTH CONDUCTOR
MATERIALPLASTIC ETHYLENE-TETRAFLUOROETHYLENE FIRST POSITION PRIMARY INSULATION FIRST CONDUCTOR
MATERIALPLASTIC ETHYLENE-TETRAFLUOROETHYLENE FIRST POSITION PRIMARY INSULATION THIRD CONDUCTOR
ROUND CONDUCTOR SIZE14 AWG ALL CONDUCTORS
VOLTAGE RATING600.0 MAXIMUM PEAK OPERATING VOLTAGE ALL CONDUCTORS
STRAND AWG SIZE PER CONDUCTOR27 ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR19 ALL CONDUCTORS
SURFACE TREATMENTTIN CORE CONDUCTOR ALL CONDUCTORS
TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE81349 FIRST END ALL CONDUCTORS
TERMINAL LUG APERTURE SIZE0.143 INCHES SECOND END ALL CONDUCTORS
TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBERM23056-106 SECOND END ALL CONDUCTORS
TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBERMS27656T17B6P FIRST END ALL CONDUCTORS
TERMINATION TYPECONNECTOR RECEPTACLE FIRST END ALL CONDUCTORS
TERMINATION TYPELUG TERMINAL W/MOUNTING HOLE SECOND END ALL CONDUCTORS


Click here to Register for Free 30-day Trial