| CONDUCTOR ARRANGEMENT AND QUANTITY | 27 SINGLES |
| CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
| CONDUCTOR QUANTITY | 27 |
| CROSS SECTION OUTSIDE DIAMETER | 0.907 INCHES NOMINAL |
| CRITICALITY CODE JUSTIFICATION | AGAV |
| CROSS-SECTIONAL SHAPE STYLE | ROUND |
| FSC APPLICATION DATA | REMOTE CONTROL,GUIDED MISSILE |
| NUCLEAR HARDNESS CRITICAL FEATURE | HARDENED |
| OVERALL LENGTH | 115.667 FEET |
| MATERIAL | COPPER 1ST POSITION SHIELD BRAID, METALLIC CABLE |
| MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS |
| MATERIAL | PLASTIC 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
| MATERIAL | RUBBER SYNTHETIC 3RD POSITION JACKET CABLE |
| MATERIAL | TIN 2ND POSITION COATING CABLE |
| ROUND CONDUCTOR SIZE | 16 AWG ALL CONDUCTORS |
| STRAND AWG SIZE PER CONDUCTOR | 29 ALL CONDUCTORS |
| STRAND QUANTITY PER CONDUCTOR | 19 ALL CONDUCTORS |
| STYLE DESIGNATOR | INTERNAL CONNECTOR AND LUG |
| TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE | 81205 1ST END ALL CONDUCTORS |
| TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE | 81205 BOTH ENDS ALL CONDUCTORS |
| TERMINAL LUG APERTURE SIZE | 0.193 INCHES 2ND END ALL CONDUCTORS |
| TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBER | BACC45DS16C05P 1ST END ALL CONDUCTORS |
| TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBER | BACT12AC8 2ND END ALL CONDUCTORS |
| TERMINATION TYPE | CONNECTOR PLUG 1ST END ALL CONDUCTORS |
| TERMINATION TYPE | LUG TERMINAL W/MOUNTING HOLE 2ND END ALL CONDUCTORS |