CROSS-SECTIONAL SHAPE STYLE | ROUND |
CONDUCTOR QUANTITY | 54 |
CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
TERMINATION TYPE | CONNECTOR PLUG BOTH ENDS ALL CONDUCTORS |
OVERALL LENGTH | 16.500 FEET |
MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS |
| PLASTIC POLYAMIDE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
| RUBBER CHLOROPRENE CLASS CR 1ST POSITION JACKET CABLE |
SURFACE TREATMENT | TIN CORE CONDUCTOR ALL CONDUCTORS |
CONDUCTOR ARRANGEMENT AND QUANTITY | 34 SINGLES AND |
| 7 TWISTED PAIR AND |
| 2 TRIPLES |
CONDUCTOR GROUPING ARRANGEMENT TYPE AND QUANTITY | 7 TWISTED PAIR AND |
| 2 TRIPLES THIRD GROUP |
COLOR CODING DOCUMENT | 2279204-10001 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
STYLE DESIGNATOR | INTERNAL ANGLE AND INTERNAL STRAIGHT CONNECTOR |
CROSS SECTION OUTSIDE DIAMETER | 0.962 INCHES NOMINAL |
TEMP RATING | 105.0 DEG CELSIUS |
TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBER | 2265763-1 1ST END ALL CONDUCTORS |
| 2424660 2ND END ALL CONDUCTORS |
TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE | 10001 1ST END ALL CONDUCTORS |
| 10001 BOTH ENDS ALL CONDUCTORS |
TEST DATA DOCUMENT | 10001-2279204 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
FSC APPLICATION DATA | FIRE CONTROL MAINTENANCE |
SPECIAL FEATURES | CABLE CONSISTS OF 4 NO. 12AWG CONDUCTORS AND 50 NO. 18AWG CONDUCTORSOF WHICH 7 PAIRS AND 2 TRIPPLES ARE SHIELDED GROUPS |
THE MANUFACTURERS DATA | |
MANUFACTURERS CODE | 10001 |
DESIGN CONTROL REFERENCE | 2279204 |