| COLOR CODING DOCUMENT | 25-32849-81205 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)25-32849-81205 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
| COLOR | WHITE FIRST POSITION COVER FIRST CONDUCTORWHITE FIRST POSITION COVER FIRST CONDUCTOR |
| CONDUCTOR ARRANGEMENT AND QUANTITY | 2 SINGLES2 SINGLES |
| CONDUCTOR QUANTITY | 22 |
| CONDUCTOR FORM | STRANDED ALL CONDUCTORSSTRANDED ALL CONDUCTORS |
| CROSS SECTION OUTSIDE DIAMETER | 0.488 INCHES NOMINAL0.488 INCHES NOMINAL |
| CROSS-SECTIONAL SHAPE STYLE | ROUNDROUND |
| FSC APPLICATION DATA | GUIDED MISSILE LAUNCHING CONTROL GROUPS |
| INDIVIDUAL CONDUCTOR LENGTH | 6.000 INCHES NOMINAL SECOND END ALL CONDUCTORS6.000 INCHES NOMINAL SECOND END ALL CONDUCTORS |
| MATERIAL DOCUMENT AND CLASSIFICATION | L-P-390,TYPE 2,GRADE 7 FED SPEC SINGLE MATERIAL RESPONSE FIRST POSITION PRIMARY INSULATION ALL CONDUCTORSL-P-390,TYPE 2,GRADE 7 FED SPEC SINGLE MATERIAL RESPONSE FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS |
| MATERIAL | GLASS FIBER SECOND POSITION BRAID NON-METALLIC ALL CONDUCTORSGLASS FIBER SECOND POSITION BRAID NON-METALLIC ALL CONDUCTORS |
| MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORSCOPPER CORE CONDUCTOR ALL CONDUCTORS |
| MATERIAL | PLASTIC POLYAMIDE NYLON THIRD POSITION JACKET ALL CONDUCTORS |
| MATERIAL | PLASTIC, POLYETHYLENE (PP) FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS |
| OVERALL LENGTH | 42.500 FEET42.500 FEET |
| ROUND CONDUCTOR SIZE | 12 AWG ALL CONDUCTORS12 AWG ALL CONDUCTORS |
| STRAND AWG SIZE PER CONDUCTOR | 28 ALL CONDUCTORS28 ALL CONDUCTORS |
| STRAND QUANTITY PER CONDUCTOR | 37 ALL CONDUCTORS37 ALL CONDUCTORS |
| STYLE DESIGNATOR | EXTERNAL ANGLE CONNECTOR AND LUG |
| SURFACE TREATMENT | TIN CORE CONDUCTOR ALL CONDUCTORS |
| TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE | 81205 FIRST END ALL CONDUCTORS81205 FIRST END ALL CONDUCTORS |
| TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE | 81205 SECOND END ALL CONDUCTORS81205 SECOND END ALL CONDUCTORS |
| TERMINAL LUG APERTURE SIZE | 0.375 INCHES SECOND END ALL CONDUCTORS0.375 INCHES SECOND END ALL CONDUCTORS |
| TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBER | BACC45DS12C01P FIRST END ALL CONDUCTORSBACC45DS12C01P FIRST END ALL CONDUCTORS |
| TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBER | BACT12AC14 SECOND END ALL CONDUCTORSBACT12AC14 SECOND END ALL CONDUCTORS |
| TERMINATION TYPE | CONNECTOR PLUG FIRST END ALL CONDUCTORSCONNECTOR PLUG FIRST END ALL CONDUCTORS |
| TERMINATION TYPE | LUG TERMINAL W/MOUNTING HOLE SECOND END ALL CONDUCTORSLUG TERMINAL W/MOUNTING HOLE SECOND END ALL CONDUCTORS |
| VOLTAGE RATING | 3000.0 DIELECTRIC TEST VOLTAGE ALL CONDUCTORS3000.0 DIELECTRIC TEST VOLTAGE ALL CONDUCTORS |