5315-01-474-9095 PIN,COTTER Index 7310-01-474-9097 ADAPTER,DISPENSING,COFFEE URN

National Stock Number:
6145-01-474-9096

Federal Supply Class:
6145

National Item Identification Number:
014749096

Description:
CABLE,POWER,ELECTRICAL

Detail:
Two or more individually insulated conductors (solid or stranded) contained in a common covering, or two or more individually insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering or shield; each having characteristics not completely conforming to CABLE, TELEPHONE; CABLE, POWER, ELECTRICAL; CABLE, RADIO FREQUENCY or CORD, ELECTRICAL. Includes items having the combined characteristics of two or more of the aforementioned names. Refers to bulk quantities only; for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, SPECIAL PURPOSE, ELECTRICAL.


Manufacturer Information:
5MD1-20C7-UN8V613THE BOEING COMPANY
M27500B20WR7U001P787NATIONAL ELECTRICAL MFRS ASSN DBA NEMA
NEMA WC275001P787NATIONAL ELECTRICAL MFRS ASSN DBA NEMA
M27500B20WR7U0081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-2750081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-DTL-2750081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
NEMA-WC275001P787NATIONAL ELECTRICAL MFRS ASSN DBA NEMA


Techincal Specification:
COLORBLUE FIRST POSITION PRIMARY INSULATION SECOND CONDUCTOR
COLORGREEN FIRST POSITION PRIMARY INSULATION FOURTH CONDUCTOR
COLORBLACK FIRST POSITION PRIMARY INSULATION SIXTH CONDUCTOR
COLORRED FIRST POSITION PRIMARY INSULATION FIRST CONDUCTOR
COLORWHITE FIRST POSITION PRIMARY INSULATION FIFTH CONDUCTOR
COLORYELLOW FIRST POSITION PRIMARY INSULATION THIRD CONDUCTOR
CONDUCTOR ARRANGEMENT AND QUANTITY7 SINGLES
CONDUCTOR FORMSTRANDED ALL CONDUCTORS
CONDUCTOR QUANTITY7
CRITICALITY CODE JUSTIFICATIONFEAT
CROSS-SECTIONAL SHAPE STYLEFLAT
MATERIALCOPPER CORE CONDUCTOR ALL CONDUCTORS
MATERIALPLASTIC POLYIMIDE FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS
MATERIALPLASTIC POLYTETRAFLUOROETHYLENE SECOND POSITION SECONDARY INSULATION ALL CONDUCTORS
ROUND CONDUCTOR SIZE20.000 AWG ALL CONDUCTORS
SPECIAL FEATURESWEAPON SYSTEM ESSNTIAL
STRAND AWG SIZE PER CONDUCTOR32 ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR19 ALL CONDUCTORS
SURFACE TREATMENTNICKEL CORE CONDUCTOR ALL CONDUCTORS
TEMP RATING200.0 CELSIUS
VOLTAGE RATING600.0 MAXIMUM PEAK OPERATING VOLTAGE ALL CONDUCTORS