5340-01-435-8747 BRACKET,ANGLE Index 5310-01-435-8749 WASHER,FLAT

National Stock Number:
6145-01-435-8748

Federal Supply Class:
6145

National Item Identification Number:
014358748

Description:
CABLE,SPECIAL PURPOSE,ELECTRICAL

Detail:
Two or more individually insulated conductors (solid or stranded) contained in a common covering, or two or more individually insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering or shield; each having characteristics not completely conforming to CABLE, TELEPHONE; CABLE, POWER, ELECTRICAL; CABLE, RADIO FREQUENCY or CORD, ELECTRICAL. Includes items having the combined characteristics of two or more of the aforementioned names. Refers to bulk quantities only; for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, SPECIAL PURPOSE, ELECTRICAL.


Manufacturer Information:
3659/9533873M COMPANY
3659/975037MINNESOTA MINING AND MFG CO 3M COMPANY
3659/9763813M COMPANY


Techincal Specification:
CONDUCTOR QUANTITY9
CONDUCTOR FORMSTRANDED ALL CONDUCTORS
MATERIALCOPPER CORE CONDUCTOR ALL CONDUCTORS
PLASTIC POLYVINYL CHLORIDE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS
PAPER 2ND POSITION SEPARATOR CABLE
ALUMINUM AND
PLASTIC POLYESTER 2ND POSITION SHIELD FOIL CABLE
COPPER 3RD POSITION SHIELD BRAID, METALLIC CABLE
PLASTIC POLYVINYL CHLORIDE 4TH POSITION JACKET CABLE
PAPER 4TH POSITION SEPARATOR CABLE
PLASTIC POLYVINYL CHLORIDE 5TH POSITION JACKET CABLE
SURFACE TREATMENTTIN CORE CONDUCTOR ALL CONDUCTORS
TIN 3RD POSITION SHIELD BRAID, METALLIC CABLE
ROUND CONDUCTOR SIZE28 AWG ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR7 ALL CONDUCTORS
STRAND AWG SIZE PER CONDUCTOR36 ALL CONDUCTORS
CONDUCTOR ARRANGEMENT AND QUANTITY10 SINGLES
COLORBLACK 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS
VOLTAGE RATING150.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
CROSS-SECTIONAL SHAPE STYLEROUND
TEMP RATING-20.0 DEG CELSIUS AND
80.0 DEG CELSIUS
SPECIAL FEATURESRED MARKING ON ONE EDGE OF INNER CABLE AND FOLDED CONSTRUCTION PERMITS MASS TERMINATION.