5365-01-412-9792 SPACER,SLEEVE Index 6145-01-412-9794 CABLE,SPECIAL PURPOSE,ELECTRICAL

National Stock Number:
6145-01-412-9793

Federal Supply Class:
6145

National Item Identification Number:
014129793

Description:
CABLE,SPECIAL PURPOSE,ELECTRICAL

Detail:
Two or more individually insulated conductors (solid or stranded) contained in a common covering, or two or more individually insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering or shield; each having characteristics not completely conforming to CABLE, TELEPHONE; CABLE, POWER, ELECTRICAL; CABLE, RADIO FREQUENCY or CORD, ELECTRICAL. Includes items having the combined characteristics of two or more of the aforementioned names. Refers to bulk quantities only; for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, SPECIAL PURPOSE, ELECTRICAL.


Manufacturer Information:
144670BTB3FL INDUSTRIES INC FL SURPRENANT WIRE AND CABLE DIV
178-221-0277229PHILADELPHIA INSULATED WIRE CO INC
357-88912814AMPHENOL CABLE AND INTERCONNECT TECHNOLOGIES, INC.
D2342-288277THE BOEING COMPANY
DMS2342-288277THE BOEING COMPANY
2013AJ-D2342-288277THE BOEING COMPANY


Techincal Specification:
CONDUCTOR ARRANGEMENT AND QUANTITY3 SINGLES
CONDUCTOR FORMSTRANDED ALL CONDUCTORS
CROSS SECTION OUTSIDE DIAMETER0.280 INCHES NOMINAL
CROSS-SECTIONAL SHAPE STYLEROUND
MATERIAL DOCUMENT AND CLASSIFICATIONASTM B298 ASSN STD SINGLE MATERIAL RESPONSE 3RD POSITION SHIELD BRAID, METALLIC FIRST CONDUCTOR
MATERIAL DOCUMENT AND CLASSIFICATIONASTM B298 ASSN STD SINGLE MATERIAL RESPONSE 2ND POSITION SHIELD BRAID, METALLIC FIRST CONDUCTOR
MATERIAL DOCUMENT AND CLASSIFICATIONASTM B355 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS
MATERIALCOPPER 2ND POSITION SHIELD BRAID, METALLIC FIRST CONDUCTOR
MATERIALCOPPER 3RD POSITION SHIELD BRAID, METALLIC FIRST CONDUCTOR
MATERIALCOPPER CORE CONDUCTOR ALL CONDUCTORS
MATERIALPLASTIC FLUORINATED ETHYLENE PROPYLENE 4TH POSITION JACKET FIRST CONDUCTOR
MATERIALPLASTIC FLUORINATED ETHYLENE PROPYLENE 5TH POSITION JACKET CABLE
MATERIALPLASTIC POLYTETRAFLUOROETHYLENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS
III CONDUCTOR QUANTITY3
III PRECIOUS MATERIAL AND LOCATIONSURFACE OF INNER AND OUTER SHIELD ON CONDUCTOR NUMBER ONE ONLY SILVER
III PRECIOUS MATERIALSILVER
PROPRIETARY CHARACTERISTICSPACS
ROUND CONDUCTOR SIZE22 AWG ALL CONDUCTORS
SPECIAL FEATURESCAPACITANCE: 29 PF/FT +/- 2 PF/FT @ 20C @ 1KHZ; DCR PER 1000 FT @ 20C = 15.7 OHMS; DIELECTRIC BREAKDOWN: CONDUCTOR TO CONDUCTOR = 2500 V RMS, CONDUCTOR TO SHIELD = 3000 V RMS
STRAND AWG SIZE PER CONDUCTOR34 ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR19 ALL CONDUCTORS
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONASTM B298 ASSN STD SINGLE TREATMENT RESPONSE 2ND POSITION SHIELD BRAID, METALLIC FIRST CONDUCTOR
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONASTM B298 ASSN STD SINGLE TREATMENT RESPONSE 3RD POSITION SHIELD BRAID, METALLIC FIRST CONDUCTOR
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONASTM B355 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS
SURFACE TREATMENTNICKEL CORE CONDUCTOR ALL CONDUCTORS
SURFACE TREATMENTSILVER 2ND POSITION SHIELD BRAID, METALLIC FIRST CONDUCTOR
SURFACE TREATMENTSILVER 3RD POSITION SHIELD BRAID, METALLIC FIRST CONDUCTOR