6145-01-412-6699 CABLE,POWER,ELECTRICAL Index 6145-01-412-6701 CABLE,POWER,ELECTRICAL

National Stock Number:
6145-01-412-6700

Federal Supply Class:
6145

National Item Identification Number:
014126700

Description:
CABLE,POWER,ELECTRICAL

Detail:
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL.


Manufacturer Information:
1454/19R0T429AEROSPACE WIRE & CABLE, INC.
8365416428BELDEN WIRE & CABLE COMPANY LLC DBA BELDEN CDT ELECTRONICS DIVISION
836542W733BELDEN WIRE AND CABLE CO WIRE AND CABLE OFFICE


Techincal Specification:
CONDUCTOR QUANTITY3
CONDUCTOR FORMSTRANDED ALL CONDUCTORS
MATERIALCOPPER CORE CONDUCTOR ALL CONDUCTORS
PLASTIC FLUORINATED ETHYLENE PROPYLENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS
ALUMINUM AND
PLASTIC POLYESTER 2ND POSITION SHIELD FOIL CABLE
COPPER 3RD POSITION SHIELD BRAID, METALLIC CABLE
PLASTIC FLUORINATED ETHYLENE PROPYLENE 4TH POSITION JACKET CABLE
SURFACE TREATMENTTIN CORE CONDUCTOR ALL CONDUCTORS
TIN 3RD POSITION SHIELD BRAID, METALLIC CABLE
ROUND CONDUCTOR SIZE18 AWG ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR19 ALL CONDUCTORS
STRAND AWG SIZE PER CONDUCTOR30 ALL CONDUCTORS
CONDUCTOR ARRANGEMENT AND QUANTITY1 TRIPLES
COLORBLACK 1ST POSITION PRIMARY INSULATION FIRST CONDUCTOR
WHITE 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR
WHITE 1ST POSITION PRIMARY INSULATION THIRD CONDUCTOR
RED 4TH POSITION JACKET CABLE
VOLTAGE RATING300.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
CROSS-SECTIONAL SHAPE STYLEROUND
CROSS SECTION OUTSIDE DIAMETER0.207 INCHES NOMINAL
TEMP RATING-70.0 DEG CELSIUS AND
200.0 DEG CELSIUS


Click here to Register for Free 30-day Trial