5310-01-407-1695 WASHER,FLAT Index 5310-01-407-1697 WASHER,FLAT

National Stock Number:
6145-01-407-1696

Federal Supply Class:
6145

National Item Identification Number:
014071696

Description:
CABLE,SPECIAL PURPOSE,ELECTRICAL

Detail:
Two or more individually insulated conductors (solid or stranded) contained in a common covering, or two or more individually insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering or shield; each having characteristics not completely conforming to CABLE, TELEPHONE; CABLE, POWER, ELECTRICAL; CABLE, RADIO FREQUENCY or CORD, ELECTRICAL. Includes items having the combined characteristics of two or more of the aforementioned names. Refers to bulk quantities only; for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, SPECIAL PURPOSE, ELECTRICAL.


Manufacturer Information:
526682353711NAVAL SEA SYSTEMS COMMAND
8021620857SOUTH BAY WIRE AND CABLE COMPANY, LLC
8021651173SOUTH BAY WIRE AND CABLE COMPANY, LLC


Techincal Specification:
COLORBLACK FIRST POSITION PRIMARY INSULATION FIRST CONDUCTOR
COLORBROWN FIRST POSITION PRIMARY INSULATION FOURTH CONDUCTOR
COLORRED FIRST POSITION PRIMARY INSULATION THIRD CONDUCTOR
COLORWHITE FIRST POSITION PRIMARY INSULATION SECOND CONDUCTOR
COLORYELLOW BAR
COLORYELLOW FIRST POSITION PRIMARY INSULATION SEVENTH CONDUCTOR
COLORYELLOW SINGLE STEP
COLORGREEN ALL STEPS
COLORGREEN CHEVRON
COLORGREEN FIRST POSITION PRIMARY INSULATION EIGHTH CONDUCTOR
COLORORANGE COVER
COLORORANGE FIRST POSITION PRIMARY INSULATION NINTH CONDUCTOR
CONDUCTOR FORMSTRANDED SINGLE CONDUCTOR
CONDUCTOR QUANTITY9
CONDUCTOR ARRANGEMENT AND QUANTITY2 SINGLES AND 2 TWISTED PAIR AND 1 TRIPLES
CONDUCTOR SEQUENCE WITHIN GROUPSFIFTH CONDUCTOR AND SIXTH CONDUCTOR THIRD GROUP
CONDUCTOR SEQUENCE WITHIN GROUPSFIRST CONDUCTOR AND SECOND CONDUCTOR FIRST GROUP
CONDUCTOR SEQUENCE WITHIN GROUPSSEVENTH CONDUCTOR AND EIGHTH CONDUCTOR AND NINTH CONDUCTOR FOURTH GROUP
CONDUCTOR SEQUENCE WITHIN GROUPSTHIRD CONDUCTOR AND FOURTH CONDUCTOR SECOND GROUP
CROSS SECTION OUTSIDE DIAMETER0.665 INCHES NOMINAL
CROSS-SECTIONAL SHAPE STYLEROUND
GROUP QUANTITY4
MATERIALCOPPER CORE CONDUCTOR ALL CONDUCTORS
MATERIALCOPPER CORE CONDUCTOR ALL CONDUCTORSPLASTIC POLYURETHANE THIRD POSITION SERVING ALL CONDUCTORSPLASTIC POLYPROPYLENE FIRST POSITION PRIMARY INSULATION EIGHTH CONDUCTOR
MATERIALCOPPER FIFTH POSITION SHIELD BRAID METALLIC THIRD GROUP
MATERIALCOPPER FIFTH POSITION SHIELD BRAID METALLIC THIRD GROUPPLASTIC POLYPROPYLENE BAR
MATERIALCOPPER FIRST MORTISE
MATERIALCOPPER INSIDE RIGHT CORNER
MATERIALCOPPER OUTSIDE LEFT CORNER
MATERIALCOPPER SECOND POSITION SHIELD BRAID METALLIC SECOND CONDUCTOR
MATERIALCOPPER SECOND POSITION SHIELD BRAID METALLIC FIRST CONDUCTOR
MATERIALPLASTIC POLYURETHANE SIXTH POSITION JACKET CABLE
MATERIALPLASTIC POLYURETHANE SIXTH POSITION JACKET CABLEPLASTIC POLYPROPYLENE CHEVRON
MATERIALPLASTIC, POLYETHYLENE (PP) FIRST POSITION PRIMARY INSULATION FIRST CONDUCTOR
MATERIALPLASTIC, POLYETHYLENE (PP) FIRST POSITION PRIMARY INSULATION SECOND CONDUCTOR
MATERIALPLASTIC, POLYETHYLENE (PP) SECOND STEP
MATERIALPLASTIC, POLYETHYLENE (PP) THIRD STEP
MATERIALPLASTIC POLYETHYLENE TEREPHTHALATE (PET)(POLYESTER) FOURTH POSITION TAPE ALL GROUPS
MATERIALPLASTIC POLYETHYLENE TEREPHTHALATE (PET)(POLYESTER) FOURTH POSITION TAPE ALL GROUPSPLASTIC POLYPROPYLENE ALL STEPS
MATERIALPLASTIC POLYETHYLENE TEREPHTHALATE (PET)(POLYESTER) SECOND SEMICONDUCTOR
MATERIALPLASTIC POLYETHYLENE TEREPHTHALATE (PET)(POLYESTER) THIRD POSITION TAPE FIRST CONDUCTOR
MATERIALPLASTIC POLYETHYLENE TEREPHTHALATE (PET)(POLYESTER) THIRD POSITION TAPE SECOND CONDUCTOR
MATERIALPLASTIC POLYETHYLENE TEREPHTHALATE (PET)(POLYESTER) THIRD POSITION TAPE SECOND CONDUCTORPLASTIC POLYETHYLENE TEREPHTHALATE (PET)(POLYESTER) SECOND LIGHT EMITTING DIODE
MATERIALPLASTIC POLYETHYLENE TEREPHTHALATE (PET)(POLYESTER) THIRD POSITION TAPE SECOND CONDUCTORPLASTIC POLYPROPYLENE SINGLE STEP
MATERIALPLASTIC POLYPROPYLENE FIFTH STEP
MATERIALPLASTIC POLYPROPYLENE FIRST POSITION PRIMARY INSULATION EIGHTH CONDUCTOR
MATERIALPLASTIC POLYPROPYLENE FIRST POSITION PRIMARY INSULATION FIFTH CONDUCTOR
MATERIALPLASTIC POLYPROPYLENE COVER
MATERIALPLASTIC POLYPROPYLENE FIRST POSITION PRIMARY INSULATION SEVENTH CONDUCTORCOPPER CORE TUBE OVERALL
MATERIALPLASTIC POLYPROPYLENE FIRST POSITION PRIMARY INSULATION SIXTH CONDUCTOR
MATERIALPLASTIC POLYPROPYLENE FIRST POSITION PRIMARY INSULATION SIXTH CONDUCTORPLASTIC POLYETHYLENE TEREPHTHALATE (PET)(POLYESTER) SINGLE TRACER SECOND CONDUCTOR
MATERIALPLASTIC POLYPROPYLENE FIRST POSITION PRIMARY INSULATION FOURTH CONDUCTOR
MATERIALPLASTIC POLYPROPYLENE FIRST POSITION PRIMARY INSULATION NINTH CONDUCTOR
MATERIALPLASTIC POLYPROPYLENE FIRST POSITION PRIMARY INSULATION SEVENTH CONDUCTOR
MATERIALPLASTIC POLYPROPYLENE FIRST POSITION PRIMARY INSULATION THIRD CONDUCTOR
MATERIALPLASTIC POLYPROPYLENE FOURTH STEP
ROUND CONDUCTOR SIZE16 AWG FIFTH CONDUCTOR
ROUND CONDUCTOR SIZE16 AWG FOURTH CONDUCTOR
ROUND CONDUCTOR SIZE16 AWG SIXTH CONDUCTOR
ROUND CONDUCTOR SIZE16 AWG THIRD CONDUCTOR
ROUND CONDUCTOR SIZE18 AWG SEVENTH CONDUCTOR
ROUND CONDUCTOR SIZE18 AWG EIGHTH CONDUCTOR
ROUND CONDUCTOR SIZE22 AWG SECOND CONDUCTOR
ROUND CONDUCTOR SIZE22 AWG FIRST CONDUCTOR
STRAND AWG SIZE PER CONDUCTOR26 NINTH CONDUCTOR
STRAND AWG SIZE PER CONDUCTOR26 SEVENTH CONDUCTOR
STRAND AWG SIZE PER CONDUCTOR26 EIGHTH CONDUCTOR
STRAND AWG SIZE PER CONDUCTOR29 FOURTH CONDUCTOR
STRAND AWG SIZE PER CONDUCTOR29 FIFTH CONDUCTOR
STRAND AWG SIZE PER CONDUCTOR30 FIRST CONDUCTOR
STRAND AWG SIZE PER CONDUCTOR30 SECOND CONDUCTOR
STRAND AWG SIZE PER CONDUCTOR29 SIXTH CONDUCTOR
STRAND AWG SIZE PER CONDUCTOR29 THIRD CONDUCTOR
STRAND QUANTITY PER CONDUCTOR19 FIFTH CONDUCTOR
STRAND QUANTITY PER CONDUCTOR19 FOURTH CONDUCTOR
STRAND QUANTITY PER CONDUCTOR19 SIXTH CONDUCTOR
STRAND QUANTITY PER CONDUCTOR19 THIRD CONDUCTOR
STRAND QUANTITY PER CONDUCTOR7 EIGHTH CONDUCTOR
STRAND QUANTITY PER CONDUCTOR7 FIRST CONDUCTOR
STRAND QUANTITY PER CONDUCTOR7 NINTH CONDUCTOR
STRAND QUANTITY PER CONDUCTOR7 SECOND CONDUCTOR
STRAND QUANTITY PER CONDUCTOR7 SEVENTH CONDUCTOR
SURFACE TREATMENTTIN CORE CONDUCTOR ALL CONDUCTORS
SURFACE TREATMENTTIN CORE CONDUCTOR ALL CONDUCTORSTIN FIRST MORTISE
SURFACE TREATMENTTIN SECOND POSITION SHIELD BRAID METALLIC SECOND CONDUCTOR
SURFACE TREATMENTTIN THIRD POSITION SHIELD BRAID METALLIC THIRD GROUP
SURFACE TREATMENTTIN THIRD POSITION SHIELD BRAID METALLIC THIRD GROUPTIN INSIDE RIGHT CORNER
TEMP RATING-28.0 CELSIUS AND 65.0 CELSIUS