6145-01-406-5047 CABLE,SPECIAL PURPOSE,ELECTRICAL Index 5365-01-406-5049 SPACER,SLEEVE

National Stock Number:
6145-01-406-5048

Federal Supply Class:
6145

National Item Identification Number:
014065048

Description:
CABLE,POWER,ELECTRICAL

Detail:
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL.


Manufacturer Information:
208-0110-01095105ROCKWELL COLLINS, INC.
M070502012703JUDD WIRE INC.


Techincal Specification:
CONDUCTOR QUANTITY5
CONDUCTOR FORMSTRANDED ALL CONDUCTORS
MATERIALCOPPER CORE CONDUCTOR ALL CONDUCTORS
PLASTIC CROSS LINKED POLYETHYLENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS
PLASTIC POLYESTER 2ND POSITION WRAP CABLE
RUBBER CHLOROSULFONATED POLYETHYLENE CLASS CSM 3RD POSITION JACKET CABLE
SURFACE TREATMENTTIN CORE CONDUCTOR ALL CONDUCTORS
ROUND CONDUCTOR SIZE8 AWG ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR168 ALL CONDUCTORS
STRAND AWG SIZE PER CONDUCTOR30 ALL CONDUCTORS
CONDUCTOR ARRANGEMENT AND QUANTITY3 SINGLES
COLORBLACK 1ST POSITION PRIMARY INSULATION FIRST CONDUCTOR
WHITE 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR
RED 1ST POSITION PRIMARY INSULATION THIRD CONDUCTOR
GREEN 1ST POSITION PRIMARY INSULATION FOURTH CONDUCTOR
BLUE 1ST POSITION PRIMARY INSULATION FIFTH CONDUCTOR
BLACK 3RD POSITION JACKET CABLE
VOLTAGE RATING3000.0 AC MAXIMUM RATED WORKING VOLTAGE ALL CONDUCTORS
CROSS-SECTIONAL SHAPE STYLEROUND
CROSS SECTION OUTSIDE DIAMETER0.778 INCHES NOMINAL
TEMP RATING55.0 DEG CELSIUS AND
90.0 DEG CELSIUS