5315-01-395-5105 PIN,LOCK Index 5305-01-395-5107 SCREW,CAP,HEXAGON HEAD

National Stock Number:
6145-01-395-5106

Federal Supply Class:
6145

National Item Identification Number:
013955106

Description:
CABLE,SPECIAL PURPOSE,ELECTRICAL

Detail:
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL.


Manufacturer Information:
AS85484/80U583SAE INTERNATIONAL
AS85484/881343SOCIETY OF AUTOMOTIVE ENGINEERS INC
M85485/8-18T1A0U583SAE INTERNATIONAL
M85485/8-18T1A81343SOCIETY OF AUTOMOTIVE ENGINEERS INC
M85485/8-18T1A81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-85485/881349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
SAE-AS85485/80U583SAE INTERNATIONAL


Techincal Specification:
COLORBLACK FOURTH POSITION JACKET SINGLE CONDUCTOR
COLORVIOLET SECOND POSITION JACKET ALL CONDUCTORS
COLORWHITE FIRST POSITION PRIMARY INSULATION SINGLE CONDUCTOR
CONDUCTOR QUANTITY1
CONDUCTOR ARRANGEMENT AND QUANTITY1 SINGLES
CONDUCTOR FORMSTRANDED SINGLE CONDUCTOR
CROSS SECTION OUTSIDE DIAMETER0.113 INCHES NOMINAL
CROSS-SECTIONAL SHAPE STYLEROUND
MATERIAL DOCUMENT AND CLASSIFICATIONASTM B33 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR SINGLE CONDUCTOR
MATERIALCOPPER CORE CONDUCTOR SINGLE CONDUCTOR
MATERIALCOPPER THIRD POSITION SHIELD BRAID METALLIC SINGLE CONDUCTOR
MATERIALPLASTIC CROSS-LINKED MODIFIED ETHYLENE TETRAFLUOROETHYLENE FIRST POSITION PRIMARY INSULATION SINGLE CONDUCTOR
MATERIALPLASTIC CROSS-LINKED MODIFIED ETHYLENE TETRAFLUOROETHYLENE SECOND POSITION JACKET SINGLE CONDUCTOR
MATERIALPLASTIC CROSS-LINKED MODIFIED ETHYLENE TETRAFLUOROETHYLENE FOURTH POSITION JACKET SINGLE CONDUCTOR
ROUND CONDUCTOR SIZE18 AWG SINGLE CONDUCTOR
SPECIAL FEATURESTHERE IS A FILTER LAYER OF ABSORPTIVE COMPOUND BETWEEN THE PRIMARY INSULATION AND THE PRIMARY JACKET OF EACH CONDUCTOR.
VOLTAGE RATING600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR
STRAND AWG SIZE PER CONDUCTOR30 SINGLE CONDUCTOR
STRAND QUANTITY PER CONDUCTOR19 SINGLE CONDUCTOR
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONASTM B33 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR SINGLE CONDUCTOR
SURFACE TREATMENTTIN CORE CONDUCTOR SINGLE CONDUCTOR
SURFACE TREATMENTTIN THIRD POSITION SHIELD BRAID METALLIC SINGLE CONDUCTOR
TEMP RATING150.0 CELSIUS