5342-01-385-2710 FAIRLEAD,TUBULAR Index 5325-01-385-2712 INSERT,SCREW THREAD

National Stock Number:
6145-01-385-2711

Federal Supply Class:
6145

National Item Identification Number:
013852711

Description:
CABLE,POWER,ELECTRICAL

Detail:
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL.


Manufacturer Information:
12599347-319200US ARMY ARDEC RDECOM
C120453909CAROL CABLE CO INC ELECTRONIC DIV


Techincal Specification:
CONDUCTOR QUANTITY4
CONDUCTOR FORMSTRANDED ALL CONDUCTORS
MATERIALCOPPER CORE CONDUCTOR ALL CONDUCTORS
RUBBER 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS
PLASTIC POLYESTER 2ND POSITION WRAP CABLE
COPPER 3RD POSITION SHIELD BRAID, METALLIC CABLE
PLASTIC POLYESTER 4TH POSITION WRAP CABLE
RUBBER CHLOROSULFONATED POLYETHYLENE CLASS CSM 5TH POSITION JACKET CABLE
MATERIAL DOCUMENT AND CLASSIFICATIONASTM B33 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS
SURFACE TREATMENTTIN CORE CONDUCTOR ALL CONDUCTORS
TIN 3RD POSITION SHIELD BRAID, METALLIC CABLE
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONASTM B33 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS
ROUND CONDUCTOR SIZE18 AWG ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR41 ALL CONDUCTORS
STRAND AWG SIZE PER CONDUCTOR34 ALL CONDUCTORS
CONDUCTOR ARRANGEMENT AND QUANTITY4 SINGLES
COLORBLACK 1ST POSITION PRIMARY INSULATION FIRST CONDUCTOR
WHITE 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR
RED 1ST POSITION PRIMARY INSULATION THIRD CONDUCTOR
GREEN 1ST POSITION PRIMARY INSULATION FOURTH CONDUCTOR
BLACK 5TH POSITION JACKET CABLE
VOLTAGE RATING300.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
CROSS-SECTIONAL SHAPE STYLEROUND
CROSS SECTION OUTSIDE DIAMETER0.330 INCHES NOMINAL
TEMP RATING-20.0 DEG CELSIUS AND
60.0 DEG CELSIUS