| ELECTRICAL RESISTANCE | 78.0 OHMS IMPEDANCE |
| CONDUCTOR QUANTITY | 2 |
| CONDUCTOR ARRANGEMENT AND QUANTITY | 1 TWIN-AXIAL TWISTED |
| CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
| CROSS SECTION OUTSIDE DIAMETER | 0.235 INCHES NOMINAL |
| CROSS-SECTIONAL SHAPE STYLE | ROUND |
| MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS |
| MATERIAL | COPPER SECOND POSITION SHIELD BRAID METALLIC CABLE |
| MATERIAL | PLASTIC CROSS-LINKED POLYOLEFIN THIRD POSITION JACKET CABLE |
| MATERIAL | PLASTIC, POLYETHYLENE (PP) FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS |
| NOMINAL CAPACITANCE IN PICOFARADS | 24.5 PER FOOT |
| ROUND CONDUCTOR SIZE | 36 AWG ALL CONDUCTORS |
| SPECIAL FEATURES | ONE STRAND OF ONE CONDUCTOR SHALL BE BARE COPPER FOR IDENTIFICATION. ENGINEERING NOTE: THIS CABLE IS USEFUL IN BALANCED CABLE APPLICATIONS. |
| VOLTAGE RATING | 750.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
| STRAND AWG SIZE PER CONDUCTOR | 28 ALL CONDUCTORS |
| STRAND QUANTITY PER CONDUCTOR | 7 ALL CONDUCTORS |
| SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | ASTM B33 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
| SURFACE TREATMENT | TIN CORE CONDUCTOR ALL CONDUCTORS |
| SURFACE TREATMENT | TIN SECOND POSITION SHIELD BRAID METALLIC CABLE |