5310-01-382-1236 NUT,PLAIN,ROUND Index 5310-01-382-1238 NUT,SELF-LOCKING,KNURLED

National Stock Number:
6145-01-382-1237

Federal Supply Class:
6145

National Item Identification Number:
013821237

Description:
CABLE,POWER,ELECTRICAL

Detail:
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL.


Manufacturer Information:
C005748-0160854LOCKHEED MARTIN CORPORATION DIV LOCKHEED MARTIN INFORMATION SYSTEMS & GLOBAL SOLUTIONS
NC6530N3SJ-2K-09504569NATIONAL WIRE AND CABLE CORPORATION
S10-973804569NATIONAL WIRE AND CABLE CORPORATION


Techincal Specification:
CONDUCTOR QUANTITY3
ACCESSORY WIRE TYPE AND QUANTITY1 DRAIN
CONDUCTOR FORMSTRANDED ALL CONDUCTORS
MATERIALCOPPER CORE CONDUCTOR ALL CONDUCTORS
PLASTIC POLYVINYL CHLORIDE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS
PLASTIC POLYAMIDE 2ND POSITION JACKET ALL CONDUCTORS
COPPER 3RD POSITION SHIELD BRAID, METALLIC CABLE
ALUMINUM OR
PLASTIC POLYESTER 4TH POSITION SHIELD FOIL CABLE
COPPER 5TH POSITION SHIELD BRAID, METALLIC CABLE
PLASTIC POLYVINYL CHLORIDE 6TH POSITION JACKET CABLE
MATERIAL DOCUMENT AND CLASSIFICATIONASTM B33 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS
SURFACE TREATMENTTIN CORE CONDUCTOR ALL CONDUCTORS
TIN 3RD POSITION SHIELD BRAID, METALLIC CABLE
TIN 5TH POSITION SHIELD BRAID, METALLIC CABLE
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONASTM B33 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS
ROUND CONDUCTOR SIZE12 AWG ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR65 ALL CONDUCTORS
STRAND AWG SIZE PER CONDUCTOR30 ALL CONDUCTORS
CONDUCTOR ARRANGEMENT AND QUANTITY1 TRIPLES
COLORBLACK 1ST POSITION PRIMARY INSULATION FIRST CONDUCTOR
WHITE 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR
GREEN 1ST POSITION PRIMARY INSULATION THIRD CONDUCTOR
VOLTAGE RATING1000.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
CROSS-SECTIONAL SHAPE STYLEROUND
CROSS SECTION OUTSIDE DIAMETER0.439 INCHES NOMINAL
TEMP RATING-40.0 DEG CELSIUS AND
105.0 DEG CELSIUS


Click here to Register for Free 30-day Trial