National Stock Number:
6145-01-258-0907

Federal Supply Class:
6145

National Item Identification Number:
012580907

Description:
CABLE,SPECIAL PURPOSE,ELECTRICAL

Detail:
Two or more individually insulated conductors (solid or stranded) contained in a common covering, or two or more individually insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering or shield; each having characteristics not completely conforming to CABLE, TELEPHONE; CABLE, POWER, ELECTRICAL; CABLE, RADIO FREQUENCY or CORD, ELECTRICAL. Includes items having the combined characteristics of two or more of the aforementioned names. Refers to bulk quantities only; for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, SPECIAL PURPOSE, ELECTRICAL.


Manufacturer Information:
1134532G1528528ITT INDUSTRIES INC ITT AEROSPACE COMMUNICATIONS DIV EAST
1134532G1531550L3HARRIS TECHNOLOGIES, INC.


Techincal Specification:
COLOR CODING DOCUMENT1134532-28528 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
COLORBLACK FIRST POSITION JACKET CABLE
CONDUCTOR FORMSTRANDED ALL CONDUCTORS
CONDUCTOR QUANTITY54
CONDUCTOR ARRANGEMENT AND QUANTITY27 TWISTED PAIR
CROSS SECTION OUTSIDE DIAMETER0.705 INCHES NOMINAL
CROSS-SECTIONAL SHAPE STYLEROUND
MATERIAL DOCUMENT AND CLASSIFICATIONASTM B33 ASSN STD ALL MATERIAL RESPONSES CORE CONDUCTOR ALL CONDUCTORS
MATERIALCOPPER ALLOY 101 OR COPPER ALLOY 102 CORE CONDUCTOR ALL CONDUCTORS
MATERIALPLASTIC FLUORINATED ETHYLENE PROPYLENE FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS
ROUND CONDUCTOR SIZE24 AWG ALL CONDUCTORS
SPECIAL FEATURESOUTER JACKET CONFORMS TO MIL-I-3930 TYPE JU AND EACH TWISTED PAIR CONTAINS ONE WHITE CONDUCTOR AND ONE BLUE CONDUCTOR
VOLTAGE RATING600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
STRAND AWG SIZE PER CONDUCTOR36 ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR19 ALL CONDUCTORS
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONASTM B33-63 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS
SURFACE TREATMENTTIN CORE CONDUCTOR ALL CONDUCTORS
TEMP RATING-55.0 CELSIUS AND 125.0 CELSIUS