5340-01-216-3738 COVER,ACCESS Index 5995-01-216-3741 CABLE ASSEMBLY,SPECIAL PURPOSE,E

National Stock Number:
6145-01-216-3740

Federal Supply Class:
6145

National Item Identification Number:
012163740

Description:
CABLE,POWER,ELECTRICAL

Detail:
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL.


Manufacturer Information:
2823/392194BELDEN, INC.
977629-13B150RAYTHEON COMPANY
977629-149956RAYTHEON COMPANY
E12C0-2-9STW81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
E12C9-0-2STW81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
EC12U9-0-2STW81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
GMS9-13-12A02925500LOCKHEED MARTIN CORPORATION
MIL-C-55021/281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-DTL-55021/281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
CONDUCTOR QUANTITY3
CONDUCTOR FORMSTRANDED ALL CONDUCTORS
MATERIALCOPPER CORE CONDUCTOR ALL CONDUCTORS
PLASTIC POLYTETRAFLUOROETHYLENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS
COPPER 1ST POSITION SHIELD BRAID, METALLIC CABLE
PLASTIC POLYTETRAFLUOROETHYLENE 2ND POSITION JACKET CABLE
SILVER 2ND POSITION SHIELD BRAID, METALLIC CABLE
MATERIAL DOCUMENT AND CLASSIFICATIONASTM B298 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS
SURFACE TREATMENTSILVER CORE CONDUCTOR ALL CONDUCTORS
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONASTM B298 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS
ROUND CONDUCTOR SIZE12 AWG ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR19 ALL CONDUCTORS
STRAND AWG SIZE PER CONDUCTOR25 ALL CONDUCTORS
CONDUCTOR ARRANGEMENT AND QUANTITY1 TRIPLES
COLORWHITE 1ST POSITION JACKET CABLE
VOLTAGE RATING600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
CROSS-SECTIONAL SHAPE STYLEROUND
CROSS SECTION OUTSIDE DIAMETER0.297 INCHES NOMINAL
TEMP RATING-65.0 DEG CELSIUS AND
200.0 DEG CELSIUS
SPECIAL FEATURESPRIMARY INSULATION CONFORMS TO L-P-403 TYPE 3
PRECIOUS MATERIALSILVER
PRECIOUS MATERIAL AND LOCATIONSURFACE ALL CONDUCTORS SILVER AND
SURFACE SHIELD BRAID SILVER
SPEC/STD CONTROLLING DATA
DEFINITIVE GOVERNMENT SPEC/STD REFERENCEE12C0-2-9STW
MANUFACTURERS CODE81349
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCEMIL-DTL-55021/2


Click here to Register for Free 30-day Trial