Description:
WIRE,ELECTRICAL

Detail:
Two or more individually insulated conductors (solid or stranded) contained in a common covering, or two or more individually insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering or shield; each having characteristics not completely conforming to CABLE, TELEPHONE; CABLE, POWER, ELECTRICAL; CABLE, RADIO FREQUENCY or CORD, ELECTRICAL. Includes items having the combined characteristics of two or more of the aforementioned names. Refers to bulk quantities only; for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, SPECIAL PURPOSE, ELECTRICAL.


Manufacturer Information:
M27500B20RE1N061P787NATIONAL ELECTRICAL MFRS ASSN DBA NEMA
M27500B20RE1N0681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
NEMA-WC275001P787NATIONAL ELECTRICAL MFRS ASSN DBA NEMA
ST5M1298-20L1N676301THE BOEING COMPANY
MIL-C-2750081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
COLORRED FIRST POSITION COVER SINGLE CONDUCTOR
COLORWHITE FIRST POSITION JACKET CABLE
CONDUCTOR FORMSTRANDED SINGLE CONDUCTOR
CROSS-SECTIONAL SHAPE STYLEROUND
DEPARTURE FROM CITED DOCUMENTAS MODIFIED BY COLOR CODE
MATERIAL DOCUMENT AND CLASSIFICATIONASTM B355 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR SINGLE CONDUCTOR
MATERIALCOPPER ALLOY CORE CONDUCTOR SINGLE CONDUCTOR
ROUND CONDUCTOR SIZE20 AWG SINGLE CONDUCTOR
SPECIAL FEATURESOPTIONAL IDENTIFICATION METHOD TWO APPLIES
STRAND AWG SIZE PER CONDUCTOR32 SINGLE CONDUCTOR
STRAND QUANTITY PER CONDUCTOR19 SINGLE CONDUCTOR
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONASTM B355 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR SINGLE CONDUCTOR
SURFACE TREATMENTNICKEL CORE CONDUCTOR SINGLE CONDUCTOR
TEMP RATING260.0 CELSIUS
VOLTAGE RATING600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR