6145-01-006-6981 WIRE,ELECTRICAL Index 6145-01-006-6984 CABLE,POWER,ELECTRICAL

National Stock Number:
6145-01-006-6983

Federal Supply Class:
6145

National Item Identification Number:
010066983

Description:
CABLE,SPECIAL PURPOSE,ELECTRICAL

Detail:
Two or more individually insulated conductors (solid or stranded) contained in a common covering, or two or more individually insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering or shield; each having characteristics not completely conforming to CABLE, TELEPHONE; CABLE, POWER, ELECTRICAL; CABLE, RADIO FREQUENCY or CORD, ELECTRICAL. Includes items having the combined characteristics of two or more of the aforementioned names. Refers to bulk quantities only; for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, SPECIAL PURPOSE, ELECTRICAL.


Manufacturer Information:
2867797324CHAMPLAIN CABLE LEEDS CORPORATION
323392194BELDEN, INC.
996416428BELDEN WIRE & CABLE COMPANY LLC DBA BELDEN CDT ELECTRONICS DIVISION
5SE00389-1628638NAVAL AIR WARFARE CENTER AIRCRAFT DIVISION CODE 1.3.1 BLDG 562-1
99642W733BELDEN WIRE AND CABLE CO WIRE AND CABLE OFFICE
7368-471002BIRNBACH CO INC
M145462132MANHATTAN ELECTRIC CABLE CORP


Techincal Specification:
COLORBLACK FIRST POSITION PRIMARY INSULATION SECOND CONDUCTOR
COLORRED FIRST POSITION PRIMARY INSULATION THIRD CONDUCTOR
COLORWHITE FIRST POSITION PRIMARY INSULATION FIRST CONDUCTOR
COLORGRAY/GREY OR WHITE FOURTH POSITION JACKET CABLE
COLORGREEN FIRST POSITION PRIMARY INSULATION FOURTH CONDUCTOR
CONDUCTOR FORMSTRANDED ALL CONDUCTORS
CONDUCTOR QUANTITY4
CONDUCTOR ARRANGEMENT AND QUANTITY4 SINGLES
CROSS SECTION OUTSIDE DIAMETER0.226 INCHES NOMINAL
CROSS-SECTIONAL SHAPE STYLEROUND
MATERIAL DOCUMENT AND CLASSIFICATIONASTM B33 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS
MATERIALCOPPER THIRD POSITION SHIELD BRAID METALLIC CABLE
MATERIALCOPPER CORE CONDUCTOR ALL CONDUCTORS
MATERIALPLASTIC POLYVINYL CHLORIDE (PVC) FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS
MATERIALPLASTIC POLYVINYL CHLORIDE (PVC) FOURTH POSITION JACKET CABLE
MATERIALPLASTIC POLYAMIDE NYLON SECOND POSITION JACKET ALL CONDUCTORS
ROUND CONDUCTOR SIZE20 AWG ALL CONDUCTORS
VOLTAGE RATING600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
STRAND AWG SIZE PER CONDUCTOR32 ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR19 ALL CONDUCTORS
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONASTM B33 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS
SURFACE TREATMENTTIN CORE CONDUCTOR ALL CONDUCTORS
SURFACE TREATMENTTIN THIRD POSITION SHIELD BRAID METALLIC CABLE
TEMP RATING105.0 CELSIUS