Description:
POWER SUPPLY

Detail:
A COMPONENT WHICH CONVERTS AVAILABLE ALTERNATING CURRENT OR DIRECT CURRENT ELECTRICAL POWER INTO A FORM REQUIRED TO OPERATE ANOTHER COMPONENT OR SET. THE ITEM MAY CONSIST OF A COMBINATION OF AN INVERTOR, VIBRATOR; VIBRATOR, INTERRUPTER; VIBRATOR, SELF-RECTIFYING; INVERTOR, POWER, STATIC; WITH A TRANSFORMER AND RECTIFIER(S) EMPLOYING ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE COMPONENTS, OR THE SYNCHRONIZED SECONDARY CONTACT(S) OF A VIBRATOR, SELF-RECTIFYING; OR MAY CONSIST OF ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE RECTIFIERS AND CAPACITORS IN TRANSFORMERLESS (ALTERNATING CURRENT-DIRECT CURRENT TYPE) CIRCUITS WHICH MAY BE OF THE VOLTAGE-MULTIPLIER TYPE. THE ITEM MAY INCORPORATE A FILTER, DIRECT CURRENT POWER AND PROVISIONS FOR REGULATION OF INPUT AND/OR OUTPUT VOLTAGE. EXCLUDES BATTERY CHARGERS; ROTATING MACHINERY TYPES; SUCH AS MOTOR GENERATORS AND DYNAMOTORS, POWER SUPPLY, CAUTERY APPARATUS; POWER SUPPLY, ELECTRODIAGNOSTIC INSTRUMENTS, AND POWER SUPPLY, MOBILE RESPIRATOR.


Manufacturer Information:
ALPHA 3807-01GD0JSW7INTERNATIONAL POWER SOURCES INC
C20495-181755LOCKHEED MARTIN CORPORATION


Techincal Specification:
ELECTRICAL POWER SOURCE RELATIONSHIPOPERATING
CRITICALITY CODE JUSTIFICATIONFEAT
INPUT PHASESINGLE FIRST ALTERNATE OPERATING POWER RQMT
INPUT PHASESINGLE FOURTH ALTERNATE OPERATING POWER RQMT
INPUT PHASESINGLE THIRD ALTERNATE OPERATING POWER RQMT
INPUT PHASESINGLE SECOND ALTERNATE OPERATING POWER RQMT
INPUT CONNECTION QUANTITY1 THIRD ALTERNATE OPERATING POWER RQMT
INPUT CONNECTION QUANTITY1 FIRST ALTERNATE OPERATING POWER RQMT
INPUT CONNECTION QUANTITY1 FOURTH ALTERNATE OPERATING POWER RQMT
INPUT CONNECTION QUANTITY1 SECOND ALTERNATE OPERATING POWER RQMT
INPUT CURRENT RATING70.0 AC AMPERES NOMINAL THIRD ALTERNATE OPERATING POWER RQMT
INPUT CURRENT RATING70.0 AC AMPERES NOMINAL FIRST ALTERNATE OPERATING POWER RQMT
INPUT CURRENT RATING70.0 AC AMPERES NOMINAL FOURTH ALTERNATE OPERATING POWER RQMT
INPUT CURRENT RATING70.0 AC AMPERES NOMINAL SECOND ALTERNATE OPERATING POWER RQMT
INPUT FREQUENCY RATING
INPUT VOLTAGE RATING90.0 AC VOLTS MINIMUM AND 110.0 AC VOLTS MAXIMUM FIRST ALTERNATE OPERATING POWER RQMT
INPUT VOLTAGE RATING120.0 AC VOLTS MINIMUM AND 130.0 AC VOLTS MAXIMUM SECOND ALTERNATE OPERATING POWER RQMT
INPUT VOLTAGE RATING220.0 AC VOLTS MINIMUM AND 230.0 AC VOLTS MAXIMUM THIRD ALTERNATE OPERATING POWER RQMT
INPUT VOLTAGE RATING230.0 AC VOLTS MINIMUM AND 250.0 AC VOLTS MAXIMUM FOURTH ALTERNATE OPERATING POWER RQMT
OPERATING AMBIENT TEMP RANGE+0.1 TO 50.0 CELSIUS
OUTPUT CONNECTION QUANTITY1 SINGLE POWER OUTPUT
OUTPUT CONNECTION TYPECONNECTOR, RECEPTACLE SINGLE POWER OUTPUT
OUTPUT CONTROL LOCATIONREAR PANEL SINGLE POWER OUTPUT
OUTPUT CURRENT RATING0.0 DC MILLIAMPERES MINIMUM AND 1.5 DC MILLIAMPERES MAXIMUM SINGLE POWER OUTPUT
OUTPUT VOLTAGE RATING0.0 DC KILOVOLTS MINIMUM AND 30.0 DC KILOVOLTS MAXIMUM SINGLE POWER OUTPUT
OVERALL HEIGHT5.250 INCHES NOMINAL
OVERALL LENGTH19.000 INCHES NOMINAL
OVERALL WIDTH13.110 INCHES NOMINAL
SPECIAL FEATURESOUTPUT VOLTAGE ANALOG METER, CONTROL SELECTOR SWITCH, VOLTAGE AND CURRENT ADJUSTABLE, LOCAL CONTROL POTENTIOMETER, ELECTROSTATIC SENSITIVE DEVICE
VENTILATION DESIGN TYPECONVECTION