| INPUT VOLTAGE RATING | 115.0 AC VOLTS NOMINAL SINGLE OPERATING POWER RQMT |
| OUTPUT VOLTAGE RATING | 20.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
| 5.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
| -2.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
| -5.2 DC VOLTS NOMINAL 4TH POWER OUTPUT |
| -12.0 DC VOLTS NOMINAL 5TH POWER OUTPUT |
| -20.0 DC VOLTS NOMINAL 6TH POWER OUTPUT |
| OUTPUT CURRENT RATING | 37.5 DC AMPERES NOMINAL 1ST POWER OUTPUT |
| 230.0 DC AMPERES NOMINAL 2ND POWER OUTPUT |
| 5.0 DC AMPERES NOMINAL 3RD POWER OUTPUT |
| 10.0 DC AMPERES NOMINAL 4TH POWER OUTPUT |
| 18.0 DC AMPERES NOMINAL 5TH POWER OUTPUT |
| 37.5 DC AMPERES NOMINAL 6TH POWER OUTPUT |
| OUTPUT CONNECTION QUANTITY | 3 1ST POWER OUTPUT |
| 2 2ND POWER OUTPUT |
| 2 3RD POWER OUTPUT |
| 2 4TH POWER OUTPUT |
| 2 5TH POWER OUTPUT |
| 2 6TH POWER OUTPUT |
| OUTPUT CONNECTION TYPE | NUT-BOLT 1ST POWER OUTPUT |
| NUT-BOLT 2ND POWER OUTPUT |
| TERMINAL STRIP 3RD POWER OUTPUT |
| TERMINAL STRIP 4TH POWER OUTPUT |
| TERMINAL STRIP 5TH POWER OUTPUT |
| NUT-BOLT 6TH POWER OUTPUT |
| ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| INPUT CURRENT RATING | 30.0 AC AMPERES NOMINAL SINGLE OPERATING POWER RQMT |
| INPUT FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE OPERATING POWER RQMT |
| INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
| INPUT CONNECTION TYPE | TERMINAL STRIP SINGLE OPERATING POWER RQMT |
| INPUT CONNECTION QUANTITY | 3 SINGLE OPERATING POWER RQMT |
| SPECIAL FEATURES | POWER SUPPLY CAN BE CONVERTED TO 38037-02 BY CHANGING JUMPER AND INSTALLING APPROPRATE EUROPEAN PLUG |
| THE MANUFACTURERS DATA | |
| MANUFACTURERS CODE | 53908 |
| DESIGN CONTROL REFERENCE | 38037-01 |