| ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| FEATURES PROVIDED | PROGRAMMABLE AND OVER TEMPERATURE PROTECTION AND OVER VOLTAGE PROTECTOR |
| INPUT PHASE | SINGLE FIRST ALTERNATE OPERATING POWER RQMT |
| INPUT PHASE | SINGLE SECOND ALTERNATE OPERATING POWER RQMT |
| INPUT CONNECTION QUANTITY | 1 FIRST ALTERNATE OPERATING POWER RQMT |
| INPUT CONNECTION QUANTITY | 1 SECOND ALTERNATE OPERATING POWER RQMT |
| INPUT CONNECTION TYPE | TERMINAL STRIP FIRST ALTERNATE OPERATING POWER RQMT |
| INPUT CONNECTION TYPE | TERMINAL STRIP SECOND ALTERNATE OPERATING POWER RQMT |
| INPUT CURRENT RATING | 1500.0 AC AMPERES NOMINAL SECOND ALTERNATE OPERATING POWER RQMT |
| INPUT CURRENT RATING | 1500.0 AC AMPERES NOMINAL FIRST ALTERNATE OPERATING POWER RQMT |
| INPUT FREQUENCY RATING | |
| INPUT VOLTAGE RATING | 115.0 AC VOLTS NOMINAL FIRST ALTERNATE OPERATING POWER RQMT |
| INPUT VOLTAGE RATING | 230.0 AC VOLTS NOMINAL SECOND ALTERNATE OPERATING POWER RQMT |
| OPERATING AMBIENT TEMP RANGE | +0.1 TO 50.0 CELSIUS |
| OUTPUT CONNECTION QUANTITY | 1 SECOND POWER OUTPUT |
| OUTPUT CONNECTION QUANTITY | 1 FIRST POWER OUTPUT |
| OUTPUT CONNECTION QUANTITY | 1 THIRD POWER OUTPUT |
| OUTPUT CONNECTION TYPE | TERMINAL STRIP FIRST POWER OUTPUT |
| OUTPUT CONNECTION TYPE | TERMINAL STRIP SECOND POWER OUTPUT |
| OUTPUT CONNECTION TYPE | TERMINAL STRIP THIRD POWER OUTPUT |
| OUTPUT CONTROL LOCATION | REAR PANEL THIRD POWER OUTPUT |
| OUTPUT CONTROL LOCATION | REAR PANEL FIRST POWER OUTPUT |
| OUTPUT CONTROL LOCATION | REAR PANEL SECOND POWER OUTPUT |
| OUTPUT CURRENT RATING | 0.0 AC AMPERES MINIMUM AND 2.25 AC AMPERES MAXIMUM SECOND POWER OUTPUT |
| OUTPUT CURRENT RATING | 0.0 AC AMPERES MINIMUM AND 1.1 AC AMPERES MAXIMUM THIRD POWER OUTPUT |
| OUTPUT CURRENT RATING | 0.0 AC AMPERES MINIMUM AND 9.2 AC AMPERES MAXIMUM FIRST POWER OUTPUT |
| OUTPUT PHASE | TWO FIRST POWER OUTPUT |
| OUTPUT PHASE | TWO SECOND POWER OUTPUT |
| OUTPUT PHASE | TWO THIRD POWER OUTPUT |
| OUTPUT FREQUENCY RATING | 45.0 HERTZ MINIMUM AND 5.0 KILOHERTZ MAXIMUM FIRST POWER OUTPUT |
| OUTPUT FREQUENCY RATING | 45.0 HERTZ MINIMUM AND 5.0 KILOHERTZ MAXIMUM SECOND POWER OUTPUT |
| OUTPUT FREQUENCY RATING | 45.0 HERTZ MINIMUM AND 5.0 KILOHERTZ MAXIMUM THIRD POWER OUTPUT |
| OUTPUT VOLTAGE RATING | 0.0 AC VOLTS MINIMUM AND 260.0 AC VOLTS MAXIMUM THIRD POWER OUTPUT |
| OUTPUT VOLTAGE RATING | 0.0 AC VOLTS MINIMUM AND 130.0 AC VOLTS MAXIMUM SECOND POWER OUTPUT |
| OUTPUT VOLTAGE RATING | 0.0 AC VOLTS MINIMUM AND 32.0 AC VOLTS MAXIMUM FIRST POWER OUTPUT |
| OVERALL HEIGHT | 5.250 INCHES NOMINAL |
| OVERALL LENGTH | 19.000 INCHES NOMINAL |
| OVERALL WIDTH | 16.000 INCHES NOMINAL |
| SPECIAL FEATURES | CONSIST OF:2 EA MODEL 251B;1 EA 400SR AND 1 EA 990-302-92 CABLE PLUS ASELECTED OSCILLATOR |