| INPUT VOLTAGE RATING | 115.0 AC VOLTS NOMINAL SINGLE OPERATING POWER RQMT |
| OVERALL LENGTH | 7.250 INCHES NOMINAL |
| OUTPUT VOLTAGE RATING | 14.0 DC VOLTS MINIMUM AND |
| 16.0 DC VOLTS MAXIMUM 1ST POWER OUTPUT |
| 9.0 DC VOLTS MINIMUM AND |
| 10.0 DC VOLTS MAXIMUM 2ND POWER OUTPUT |
| 4.0 DC VOLTS MINIMUM AND |
| 6.0 DC VOLTS MAXIMUM 3RD POWER OUTPUT |
| 6.0 DC VOLTS MAXIMUM 4TH POWER OUTPUT |
| -4.0 DC VOLTS MINIMUM AND |
| -6.0 DC VOLTS MAXIMUM 5TH POWER OUTPUT |
| -10.0 DC VOLTS MINIMUM AND |
| -12.0 DC VOLTS MAXIMUM 6TH POWER OUTPUT |
| -14.0 DC VOLTS MINIMUM AND |
| -16.0 DC VOLTS MAXIMUM 7TH POWER OUTPUT |
| OUTPUT CURRENT RATING | 5.5 DC AMPERES NOMINAL 1ST POWER OUTPUT |
| 0.5 DC AMPERES NOMINAL 2ND POWER OUTPUT |
| 10.0 DC AMPERES NOMINAL 3RD POWER OUTPUT |
| 4.0 DC AMPERES NOMINAL 4TH POWER OUTPUT |
| -0.4 DC AMPERES NOMINAL 5TH POWER OUTPUT |
| -0.5 DC AMPERES NOMINAL 6TH POWER OUTPUT |
| -4.4 DC AMPERES NOMINAL 7TH POWER OUTPUT |
| OUTPUT CONNECTION QUANTITY | 1 SINGLE POWER OUTPUT |
| OUTPUT CONNECTION TYPE | CONNECTOR, RECEPTACLE SINGLE POWER OUTPUT |
| ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| INPUT FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE OPERATING POWER RQMT |
| INPUT PHASE | THREE SINGLE OPERATING POWER RQMT |
| ENVIRONMENTAL PROTECTION | FUNGUS PROOF AND |
| SALT SPRAY RESISTANT AND |
| ELECTRICALLY INSULATED |
| MAXIMUM OPERATING ALTITUDE RATING | 55000.0 FEET |
| OVERALL WIDTH | 6.250 INCHES NOMINAL |
| OVERALL HEIGHT | 5.520 INCHES NOMINAL |
| OPERATING AMBIENT TEMP RANGE | -55.0 TO 85.0 DEG CELSIUS |
| FEATURES PROVIDED | OVER VOLTAGE PROTECTOR AND |
| INPUT TO OUTPUT ISOLATION AND |
| INPUT TO CASE ISOLATION AND |
| OUTPUT TO CASE ISOLATION |