| INPUT VOLTAGE RATING | 400.0 DC VOLTS NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
| 230.0 DC VOLTS NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
| OUTPUT VOLTAGE RATING | 26.0 DC VOLTS MINIMUM AND |
| 30.0 DC VOLTS MAXIMUM 1ST POWER OUTPUT |
| 14.0 DC VOLTS MINIMUM AND |
| 16.0 DC VOLTS MAXIMUM 2ND POWER OUTPUT |
| 3.0 DC VOLTS MINIMUM AND |
| 7.0 DC VOLTS MAXIMUM 3RD POWER OUTPUT |
| -14.0 DC VOLTS MINIMUM AND |
| -16.0 DC VOLTS MAXIMUM 4TH POWER OUTPUT |
| OUTPUT CURRENT RATING | 1.0 DC AMPERES NOMINAL 1ST POWER OUTPUT |
| 0.25 DC AMPERES NOMINAL 2ND POWER OUTPUT |
| 0.25 DC AMPERES NOMINAL 3RD POWER OUTPUT |
| -0.25 DC AMPERES NOMINAL 4TH POWER OUTPUT |
| INPUT FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE OPERATING POWER RQMT |
| INPUT PHASE | THREE SINGLE OPERATING POWER RQMT |
| POWER SUPPLY EFFICIENCY LINE | 90.0 |
| MAXIMUM OPERATING ALTITUDE RATING | 45000.0 FEET |
| WARM UP TIME IN MINUTES | 5 |
| OPERATING AMBIENT TEMP RANGE | -30.0 TO 170.0 DEG FAHRENHEIT |
| FEATURES PROVIDED | INPUT TO OUTPUT ISOLATION AND |
| INPUT TO CASE ISOLATION AND |
| OUTPUT TO CASE ISOLATION AND |
| EMI FILTER AND |
| OVER TEMPERATURE PROTECTION |
| NUCLEAR HARDNESS CRITICAL FEATURE | HARDENED |
| FSC APPLICATION DATA | POWER SUPPLY ASSEMBLY 5865-01-187-5724 |
| SPECIAL FEATURES | COOLING BY CONDUCTION TO A CHILL PLATE |
| REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | DIFFERENTIATED BY REPAIR PARTS |
| SPEC/STD CONTROLLING DATA | |
| MANUFACTURERS CODE | 00752 |
| MFR SOURCE CONTROLLING REFERENCE | 435297-1 |
| THE MANUFACTURERS DATA | |
| MANUFACTURERS CODE | 09062 |
| DESIGN CONTROL REFERENCE | 83D0056-1 |