Detail:
A COMPONENT WHICH CONVERTS AVAILABLE ALTERNATING CURRENT OR DIRECT CURRENT ELECTRICAL POWER INTO A FORM REQUIRED TO OPERATE ANOTHER COMPONENT OR SET. THE ITEM MAY CONSIST OF A COMBINATION OF AN INVERTOR, VIBRATOR; VIBRATOR, INTERRUPTER; VIBRATOR, SELF-RECTIFYING; INVERTOR, POWER, STATIC; WITH A TRANSFORMER AND RECTIFIER(S) EMPLOYING ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE COMPONENTS, OR THE SYNCHRONIZED SECONDARY CONTACT(S) OF A VIBRATOR, SELF-RECTIFYING; OR MAY CONSIST OF ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE RECTIFIERS AND CAPACITORS IN TRANSFORMERLESS (ALTERNATING CURRENT-DIRECT CURRENT TYPE) CIRCUITS WHICH MAY BE OF THE VOLTAGE-MULTIPLIER TYPE. THE ITEM MAY INCORPORATE A FILTER, DIRECT CURRENT POWER AND PROVISIONS FOR REGULATION OF INPUT AND/OR OUTPUT VOLTAGE. EXCLUDES BATTERY CHARGERS; ROTATING MACHINERY TYPES; SUCH AS MOTOR GENERATORS AND DYNAMOTORS, POWER SUPPLY, CAUTERY APPARATUS; POWER SUPPLY, ELECTRODIAGNOSTIC INSTRUMENTS, AND POWER SUPPLY, MOBILE RESPIRATOR.


Manufacturer Information:
JF751B-8000-902808742ASTEC AMERICA INC.
PM2497-A-1-36D22-0-1D-4-6-8T08676PIONEER MAGNETICS, INC.


Techincal Specification:
ELECTRICAL POWER SOURCE RELATIONSHIPOPERATING
FEATURES PROVIDEDCIRCUIT OVERLOAD PROTECTION DEVICE AND REMOTE ERROR SENSING CAPABILITY AND OVER TEMPERATURE PROTECTION
INPUT FREQUENCY RATING
INPUT VOLTAGE RATING184.0 AC VOLTS MINIMUM AND 250.0 AC VOLTS MAXIMUM SECOND OPERATING POWER RQMT
INPUT VOLTAGE RATING24.0 DC VOLTS MINIMUM AND 240.0 DC VOLTS MAXIMUM THIRD OPERATING POWER RQMT
INPUT PHASESINGLE SINGLE OPERATING POWER RQMT
INPUT VOLTAGE RATING92.0 AC VOLTS MINIMUM AND 138.0 AC VOLTS MAXIMUM FIRST OPERATING POWER RQMT
OUTPUT CURRENT RATING22.0 DC AMPERES NOMINAL SINGLE POWER OUTPUT
OUTPUT VOLTAGE RATING36.0 DC VOLTS NOMINAL SINGLE POWER OUTPUT
OVERALL HEIGHT5.000 INCHES NOMINAL
OVERALL LENGTH11.000 INCHES NOMINAL
OVERALL WIDTH8.000 INCHES NOMINAL