| DUTY CYCLE | CONTINUOUS |
| ENCLOSURE FEATURE | TOTALLY ENCLOSED |
| COOLING METHOD | SELF-VENTILATED |
| FEATURES PROVIDED | HORIZONTAL MOUNTING POSITION |
| FRAME SIZE DESIGNATION | TA1 |
| INCLOSURE SPECIFICATION | COMMERCIAL |
| LENGTH OF SHAFT FROM HOUSING | 0.810 INCHES IDENTICAL ENDS |
| MOUNTING FACILITY TYPE AND QUANTITY | 8 THREADED HOLE(S) |
| MOUNTING METHOD | FIXED BASE |
| NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.940 INCHES |
| NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.125 INCHES |
| OVERALL HEIGHT | 2.510 INCHES |
| OVERALL LENGTH | 3.560 INCHES |
| OVERALL WIDTH | 2.750 INCHES |
| PHASE | THREE INPUT |
| SHAFT END STYLE | SUNK KEYWAY IDENTICAL ENDS |
| SHAFT DIAMETER | 0.249 INCHES NOMINAL SINGLE END |
| SHAFT ROTATION DIRECTION | CLOCKWISE OR COUNTERCLOCKWISE IDENTICAL ENDS |
| TERMINAL TYPE AND QUANTITY | 4 SOLDER LUG |
| WINDING TYPE | INDUCTION-PERMANENT SPLIT CAPACITOR SPLIT PHASE |