| BINDING METHOD | SLEEVE |
| BRANCH QUANTITY | 5 |
| CABLE ASSEMBLY OVERALL LENGTH | 266.000 INCHES NOMINAL |
| CONDUCTOR QUANTITY | 30 |
| MATERIAL DOCUMENT AND CLASSIFICATION | -22759/11-22-9 MIL SPEC SINGLE MATERIAL RESPONSE CORE CONDUCTOR FIFTH GROUP |
| MATERIAL DOCUMENT AND CLASSIFICATION | -27500-22RC2S05 MIL SPEC SINGLE MATERIAL RESPONSE CORE CONDUCTOR SECOND GROUP |
| MATERIAL DOCUMENT AND CLASSIFICATION | -27500-22RC2S05 MIL SPEC SINGLE MATERIAL RESPONSE CORE CONDUCTOR THIRD GROUP |
| MATERIAL DOCUMENT AND CLASSIFICATION | 8421527, CAGE97151 MIL SPEC SINGLE MATERIAL RESPONSE CORE CONDUCTOR FOURTH GROUP |
| MATERIAL DOCUMENT AND CLASSIFICATION | 8421527, CAGE 97151 MIL SPEC SINGLE MATERIAL RESPONSE CORE CONDUCTOR FIRST GROUP |
| MATERIAL | COPPER THIRD POSITION SHIELD BRAID METALLIC FOURTH GROUP |
| MATERIAL | COPPER THIRD POSITION SHIELD BRAID METALLIC FIRST GROUP |
| MATERIAL | COPPER ALLOY CORE CONDUCTOR FIRST GROUP |
| MATERIAL | COPPER ALLOY CORE CONDUCTOR FOURTH GROUP |
| MATERIAL | COPPER CORE CONDUCTOR FIFTH GROUP |
| MATERIAL | COPPER CORE CONDUCTOR SECOND GROUP |
| MATERIAL | COPPER CORE CONDUCTOR THIRD GROUP |
| MATERIAL | COPPER SECOND POSITION SHIELD BRAID METALLIC SECOND GROUP |
| MATERIAL | COPPER SECOND POSITION SHIELD BRAID METALLIC THIRD GROUP |
| MATERIAL | COPPER SECOND POSITION SHIELD BRAID METALLIC FIRST GROUP |
| MATERIAL | COPPER SECOND POSITION SHIELD BRAID METALLIC FOURTH GROUP |
| MATERIAL | PLASTIC ETHYLENE-TETRAFLUOROETHYLENE FIRST POSITION PRIMARY INSULATION FIRST GROUP |
| MATERIAL | PLASTIC ETHYLENE-TETRAFLUOROETHYLENE FOURTH POSITION JACKET FIRST GROUP |
| MATERIAL | PLASTIC ETHYLENE-TETRAFLUOROETHYLENE FOURTH POSITION JACKET FOURTH GROUP |
| MATERIAL | PLASTIC ETHYLENE-TETRAFLUOROETHYLENE FIRST POSITION PRIMARY INSULATION FOURTH GROUP |
| MATERIAL | PLASTIC FLUORINATED ETHYLENE PROPYLENE THIRD POSITION JACKET SECOND GROUP |
| MATERIAL | PLASTIC FLUORINATED ETHYLENE PROPYLENE THIRD POSITION JACKET THIRD GROUP |
| MATERIAL | PLASTIC POLYTETRAFLUOROETHYLENE FIRST POSITION PRIMARY INSULATION SECOND GROUP |
| MATERIAL | PLASTIC POLYTETRAFLUOROETHYLENE FIRST POSITION PRIMARY INSULATION THIRD GROUP |
| MATERIAL | PLASTIC POLYTETRAFLUOROETHYLENE FIRST POSITION PRIMARY INSULATION FIFTH GROUP |
| MATERIAL | SILVER SECOND POSITION COATING SECOND GROUP |
| MATERIAL | SILVER SECOND POSITION COATING THIRD GROUP |
| MATERIAL | TIN SECOND POSITION COATING FIRST GROUP |
| MATERIAL | TIN SECOND POSITION COATING FOURTH GROUP |
| MATERIAL | TIN THIRD POSITION COATING FIRST GROUP |
| MATERIAL | TIN THIRD POSITION COATING FOURTH GROUP |
| PRECIOUS MATERIAL AND LOCATION | CONTACT SURFACES GOLD AND CONTACT AND CONDUCTOR SURFACES SILVER |
| PRECIOUS MATERIAL | SILVER AND GOLD |
| SPECIAL FEATURES | EACH GROUP IS A BRANCH. GROUP 1 IS P1 WITH CONNECTOR KJAIII443-710 CAGE 71468, GROUP 2 IS P3 WITH CONNECTOR D38999/26WE35PN CAGE 77820, GROUP 3 IS P4 CONNECTOR MS27467T13F35S CAGE 77820, GROUP 4 IS J2 WITH CONNECTOR 12465066-1 CAGE 77820, GROUP 5 IS J3 WITH CONNECTOR D38999/24WB5PN CAGE 77820. P2 CONNECTOR TV06RW25-17S CAGE 77820, CONTACTS T3-47TB08-LD CAGE 49367 WITH INDEXING KEYWAY. MORE DETAILS ON DRAWING IN COLUMBUS JEDMICS. |
| SURFACE TREATMENT | SILVER CORE CONDUCTOR ALL CONDUCTORS |
| TERMINATION TYPE | CONNECTOR ALL ENDS ALL CONDUCTORS |